- 26 -
9-2
Screws do not flow.
・
Screws in an abnormal position in
the passing plate cannot be swept
away with the brush.
・
The axis of the screw thread
entered the passing plate.
・
A screw has stopped in an abnormal
position while moving on the rail.
・
The rail does not vibrate.
(For example, a screw is obstructing
the clearance in scooping chamber.)
・
Adjust the brush.
Adjust the passing plate.
If a proper amount of screws are
loaded into the scooping chamber
the status may be improved.
Use the optional brush. (stiffer bristles)
[Parts No: NSB02053 #02]
・
Remove the abnormal screw
and check and adjust the
passing plate.
・
Remove the screw in the
abnormal position. Take care not
to damage the rail groove.
Move the holding plate bracket
assembly upward to remove the
screw. After, adjust the position
of the holding plate.
・
Remove the screw that is
obstructing the clearance.
・
Check the vibration adjustment.
If no screw is obstructing the
clearance, consult our service
section.
Trouble
Cause
Corrective measures