- 23 -
接続例
7
-
2
.
External output signals
The wires coming out from the back of the machine serves as the detection of
presence of screws on the rotational escaper, which shall be used with auto-
matic assembly machines or external screw counters.
[Function]: Screw present: signal high (ON)
Incoming current: shall be limited to less than 100mA
**CAUTION: Additional resistor is required on external circuit for
regulating current **
[Capacity]: Max DC current: 100mA
External supply voltage: 5 ~24VDC (Max: 27VDC)
[caution]: Please keep the length of output signal wire less than 3m;
* The purple wire functions as signal output high (Collector end),
with the gray wire as common (Emitter end)
Purple line--->Signal line (OFF when no screw is present)
(On when a screw is present)
Gray line --->Common line
Grommet
Signal line
(CN10)
Inside of the feeder
Outside of the feeder
Purple line
Gray line
Circuit diagram of the signal lines