Only qualified personal should attempt to work on this equipment.
There
is not much to go wrong with the OD 4000 punch. Most of the
problems are due to setup error. There are two fuses located at the rear of the
punch that can be replaced by the customer. Here is a small troubleshooting
guide to help you through some of the problems that may be encountered.
Symptom
Machine does not cycle.
Troubleshooting
I
Possible Cause
I
Action
1) Machine is off. 1) Check power switch.
2)
Machine not plugged in. 2)
Check both ends of power
Foot pedal not plugged
into machine.
Top Cover Switch.
Blown fuse.
Pin retainer interference.
Punch stopped in mid
cycle.
Pins
not flush
with pin
retainer.
cord.
3) Make sure foot pedal cable is
attached to machine.
4) Close top cover.
5) Check Fuse 1 (5A).
slot in pusher bar. (see
2) Check fuses and restart
Make sure that all the pins are
OD
4000
Electrical Schematic
This product has earned the UL Listing Mark and the UL Listing Mark for
Canada. E179574. The OD 4000 has been tested with a duty cycle of 20 cycles
per minute with a 2 minute rest period after 30 seconds of run time.