5.
Maintenance and Care
Every machine is only as reliable as its maintenance personnel.
It is most important that the operator carries out the following maintenance
work in shorter time periods than the normal maintenance intervals:
High Pressure Pump
First oil change to be carried out after 50 operating hours, further oil changes
due every 500 operating hours, however, min. once a year. Only OERTZEN
OSP special pump oil to be use. Take care that waste oil will be treated as per
regulations. In case the pump oil becomes turbid, carry out oil change
immediately. If oil becomes turbid again, do not operate the unit any longer.
Call qualified service.
Strainer
A strainer (6) is installed at the water inlet which has to be checked prior to
start-up and cleaned/replaced whenever necessary.
Fuel Filter
Between fuel pump and fuel tank a filter is installed which has to be
cleaned/replaced regularly.
Fuel Pump
Strainer of fuel pump (22) to be cleaned/replaced regularly.