15
8.
Trouble
Shooting
Electrical energy can cause severe injuries. Electrical components tho-
roughly and frequently to be checked for damages and malfunctions, in
order to avoid any cause for accidents. Disconnect the unit from the
electrical network during all repair/maintenance work (ZH 1/95).
Trouble Shooting: - only to be carried out by qualified service personnel.
Malfunction
Cause
Remedy
Electr. motor does not start.
Motor protection switch pushed.Push motor protection switch.
Unit not connected to power
Insert plug into socket.
source
Fuse burnt.
Replace fuse. If fuse burns
again,
call
qualified
service.
Phase in electr. plug missing. Install phase acc. to electr.
wiring
diagram.
Motor protection switch faulty. Call qualified service.
Electr. motor suddenly stops.
Fuse burnt (phase missing).
Replace fuse.
If
fuse
burns
again
or
motor
is
noisy,
call
qualified
service.
Low voltage/thermal overload. Arrange required voltage
(refer
to
techn.
data,
name
plate).
Cool
down
motor,
re-start,
call
qualified
service.
Motor protection switch faulty. Call qualified service.
Operating pressure high.
Clean/replace nozzle (refer to
techn.
data).
Electr. motor is noisy at
Fuse burnt (phase missing).
Replace fuse.
start-up. If
fuse
burns
again,
call
qualified
service.
Fault in electr. network.
Check phases in electr. plug.
Operating pressure not
Air in unit.
Bleed HP-cleaner.
achieved,
varies. Open
pressure
adjusting
handle
and
pistol
unless
stable
pressure
is
achieved.
Water shortage.
Water supply hose too small
(see table).
Nozzle
worn.
Replace
nozzle.
Incorrect
nozzle
.
Install correct nozzle.
Nozzle partly clogged.
Dismantle and clean nozzle.
Water filter clogged.
Dismantle, clean and flush.
Vibrations on high pressure
Air in unit.
Open pressure adjusting
hose and pistol.
handle and pistol unless
stable
pressure
is
achieved.
Clean strainer.
No detgergent injection.
Detergent tank empty.
Re-fill tank.
Dosing valve a/o pressure
Open.
adjusting
handle
closed.
Low pressure nozzle in
Dismantle, clean.
double
lance
clogged.
Non-return valve blocked
Blow compressed air into
detergent hose