Failure to observe the following precautions could result in damage
to the pump!
Unauthorized opening of the pump or modifications of the mechanical or
electrical components of the pump void the warranty.
The pump must only be opened by such persons who have been authori-
sed by Oerlikon Oerlikon Leybold Vacuum Vacuum to do so.
The rotor is precision balanced; any change whatsoever, such as loose-
ning or bending any rotor component, will make re-balancing necessary.
Unless appropriate accessories and attachments are used, the TURBO-
VAC
is not
suitable for aggressive or corrosive media, or those containing
dust. When handling corrosive media the C version pump must be
operated with purge gas; when handling media containing dust, a fine-
mesh filter must be installed.
Observe the information on media compatibility, to be found in Section
4.1.
Take care not to damage the plugs and coolant connections during move-
ment.
Exposure of the pump to accelerating forces must be avoided or reduced
to such an extent that the rotor unit will not be excited by vibrations. In
the case of critical applications you must consult our Applications Dept.
first.
The references to diagrams, e. g. (1/2) consist of the Fig. No. and the Item
No. in that order.
We reserve the right to alter the design or any data given in these Operating
Instructions. The illustrations are not binding.
Retain the Operating Instructions for further use.
Safety Information
5
GA05118_1502 - 12/2006 - © Oerlikon Leybold Vacuum
Caution
Figures