Design with
ISO-K
clamp flange
Fit the O-ring at the centering ring.
The O-ring should be flat and even; it must not be twisted. Then add the
outer ring.
A collar flange with retaining ring and suitable sealing washer can also be
used to connect the TURBOVAC.
A collar flange is required when using ultra-high-vacuum sealing washers.
Splinter guard
A splinter guard is installed in the high-vacuum flange to protect the
TURBO-
VAC
.
Operate the pump only with this splinter guard in place as foreign objects
passing through the intake port and into the pump can cause serious
damage to the rotor. Damage caused by foreign objects in the rotor section
is excluded from the guarantee.
Installation
18
GA05118_1502 - 12/2006 - © Oerlikon Leybold Vacuum
Fig. 5 Using ISO-K flanges
Install outer
centering ring