background image

Installation and operating instructions 
These installation and operating instructions are valid for the 
SOGEVAC pumps SV28 BI in their standard version. 
Special versions to these pumps are delivered with an additive 
document, which prevails over the standard instructions. 
The SOGEVAC vacuum pumps have been manufactured according 
to the latest technical standards and safety regulations. If not 
installed properly or not used as directed, dangerous situations or 
damage could occur. 
It is mandatory that these operating instructions be read and 
understood prior to vacuum pump installation and start-up.
 

General Instructions 

3

1.1 

Safety Instructions 

3

1.2 

Application range 

4

1.3 

Principle of operation 

4

1.4 

Technical characteristics 

5

1.5 

Accessories 

7

1.6 

Transport and Packing 

7

1.7 

Mounting orientation and storage 

8

1.8 

Lubricants 

8

Installation 

8

2.1 

Setting-up 

8

2.2 

Inlet connection 

8

2.3 

Connection to exhaust side 

9

2.4   Oil filling 

9

2.5 

Electrical connection 

9

2.6 

Operating advices 

10

2.7 

Shutdown 

10

Maintenance 

11

3.1 

Oil level 

11

3.2 

Oil change 

11

3.3 

Exhaust filters replacement 

12

3.4 

Gas ballast valve cleaning 

12

3.5 

Inlet flange sifter cleaning 

12

3.6   Anti-suckback valve  

12

3.7 

Fan cover cleaning 

12

3.8 

Checking the float valve 

12

Breakdown analysis 

12

Spare parts 

12

Information 

13 

 

EC Declaration of Conformity 

 

Declaration of contamination 

 

Spare Parts list

 

Sales and Service 

Contents

 2

GA02331_002_01 - 09/2007 - © Oerlikon Leybold Vacuum

Page

Summary of Contents for Sogevac SV28 BI

Page 1: ...Part Numbers 960 270 960 273 960 276 960 278 Sogevac SV28 BI Single stage oil sealed Rotary Vane Pump Operating Instructions GA02331_002_01 ...

Page 2: ...y Instructions 3 1 2 Application range 4 1 3 Principle of operation 4 1 4 Technical characteristics 5 1 5 Accessories 7 1 6 Transport and Packing 7 1 7 Mounting orientation and storage 8 1 8 Lubricants 8 2 Installation 8 2 1 Setting up 8 2 2 Inlet connection 8 2 3 Connection to exhaust side 9 2 4 Oil filling 9 2 5 Electrical connection 9 2 6 Operating advices 10 2 7 Shutdown 10 3 Maintenance 11 3 ...

Page 3: ...ith over atmospheric pressure Size of the exhaust line so that no pressure higher than 1 15 bar abs 0 15 bar rel or depression of 15 mbar 0 15 bar rel can occur 1 1 4 Operating of the pump without oil or operating with incorrect sense of rotation can destroy the pump 1 1 5 Never expose part of the body to the vacuum There is a danger of injury Never operate the pump with an open and thus accessibl...

Page 4: ...of the pump It is dragged off by the compressed gases and roughly separated by gravity when entering in the oil sump A fine separation is then operated in the exhaust filter The exhaust filter retains 99 9 of the aerosols An internal transfer pushes the collected oil back into the vacuum generator the transfer is operated by a float valve to avoid atmospheric air coming from the oil casing to the ...

Page 5: ... F for single phase motors Leak rate mbar l s 1 1 103 1 103 Oil type Capacity l GS32 0 5l or 1 8l Intake connection 25 KF 25 KF Exhaust connection 25 KF 25 KF Pump with three phase motor without gas ballast small oil casing 230 V 400 V 50Hz 460 V 60Hz 960 270 Pump with three phase motor gas ballast small oil casing 230 V 400 V 50Hz 460 V 60Hz 960 271 Pump with three phase motor without gas ballast...

Page 6: ...General Instructions GA02331_002_01 09 2007 Oerlikon Leybold Vacuum ...

Page 7: ...ansport and Packing SOGEVAC vacuum pumps pass a rigorous operating test in our factory and are packed to avoid transport damages Please check packing on delivery for transport damages The outer package bears a shock indicator turning red at 50 g Should the shock indicator have reacted a transportation damage may have occurred and the freight forwarder must be advised Packing materials should be di...

Page 8: ...ires a pump maintenance Please contact Oerlikon Leybold Vacuum s customer service Storage temp 15 C to 60 C 1 8 Lubricants The SOGEVAC SV28 BI pumps should be run with mineral oils for vacuum pumps with low viscosity according to ISO category VG32 The Oerlikon Leybold Vacuum oil GS32 corresponds to these prescriptions GS32 Oil Conditioning Reference 1l 711 17 772 2l 711 17 723 5l 711 17 724 20l 71...

Page 9: ...her exceed 1 15 bar absolute 0 15 bar relative nor fall under atmosphere pressure minus 15 mbar 2 4 Oil filling see chapter 1 1 4 The necessary oil is supplied in a can beside the pump To fill in the oil unscrew the oil fill plug and fill in until the oil level reaches the MAX mark beside the oil sight glass 2 5 Electrical connection see chapters 1 1 4 and 1 1 5 The electrical installation may onl...

Page 10: ...nutes with the inlet connection closed and open gas ballast to clear the oil of condensate 2 7 Shutdown The inlet flange of the SOGEVAC pumps contains an anti suck back valve It closes the inlet flange when the pump is voluntarily or accidentally shut down thus maintaining the vacuum in the connected system and preventing oil from being sucked back into the system Except the indications in chapter...

Page 11: ... months 3 7 Check the electrical connection only by a specialist 6 months To simplify the maintenance work we recommend combining several jobs 3 1 Oil level The oil level shall be checked at least once a day and must be while the pump is in operation close to the MAX mark Should the oil level be below the MIN mark switch off the pump check it see chapter 4 and add the required amount of oil 3 2 Oi...

Page 12: ...at the same time as the inlet flange sifter and if dirty be cleaned with an appropriate solvent Remove the inlet flange check if there is no damage on the sealing part of the valve 3 7 Fan cover cleaning Soiling of the fan cover may lead to overheating of the motor and the pump Put off the cover and clean it with blast air Before starting the pump again be sure that the cover has been reassembled ...

Page 13: ...erlikon Leybold Vacuum service station for repairing you have to attach the form Declaration of Contamination of Vacuum Equipment and Components The Service of Oerlikon Leybold Vacuum will send it to you on simple request specimen on the end of this manual Oerlikon Leybold Vacuum will return to the sender s address any material received without this declaration For the transport the pump and its c...

Page 14: ... 14 GA02330_002_01 09 2007 Oerlikon Leybold Vacuum ...

Page 15: ...n Process B Condition of the equipment No1 Yes No Contamination No1 Yes 1 1 Has the equipment been used toxic 2 Drained Product service fluid corrosive 3 All openings sealed airtight flammable 4 Purged explosive 2 If yes which cleaning agent radioactive 2 and which method of cleaning microbiological 2 1 If answered with No go to D other harmful substances C Description of processed substances Plea...

Page 16: ...Spare parts list 16 GA02331_002_01 09 2007 Oerlikon Leybold Vacuum ...

Page 17: ...230V 971457670 12 1 WECHSELSTROM MOTOR 115 V SINGLE PHASE MOTOR 115 V MOTEUR MONO 115V 971457680 13 1 DREHSTROM MOTOR KUGELLAGER BEARING THREE PHASE MOTOR ROULEMENT MOTEUR TRI 971464740 13 1 WECHSELSTROM MOTOR KUGELLAGER BEARING SINGLE PHASE MOTOR ROULEMENT MOTEUR MONO 971440330 14 1 GENERATOR MODUL DREHSTROM GENERATOR THREE PHASE GENERATEUR ENS TRI 971462620 Incl 22a b c d e f g n o 14 1 GENERATO...

Page 18: ...26501 Bourg lès Valence Cedex Phone 33 4 75 82 33 00 Fax 33 4 75 82 92 69 info vacuum vc oerlikon com Great Britain Oerlikon Leybold Vacuum UK LTD Unit 2 Silverglade Business Park Leatherhead Road UK Chessington Surrey KT9 2QL Sales Phone 44 13 7273 7300 Fax 44 13 7273 7301 sales vacuum ln oerlikon com Service Phone 44 20 8971 7030 Fax 44 20 8971 7003 service vacuum ln oerlikon com Italy Oerlikon ...

Page 19: ...Notes 19 GA02331_002_01 09 2007 Oerlikon Leybold Vacuum ...

Page 20: ...0 Fax 49 221 347 1250 E mail info oerlikon com www oerlikon com Oerlikon Leybold Vacuum France 640 rue A Bergès B P 107 F 26501 Bourg lès Valence Phone 33 0 4 75 82 33 00 Fax 33 0 4 75 82 92 69 E mail marketing vacuum vc oerlikon com 20 GA02331_002_01 09 2007 Oerlikon Leybold Vacuum ...