Installation
8
These operating instructions are part of the consignment. The connection ports
are blanked off by plastic protective caps or self-adhesives. Take these caps or
self-adhesives away before turning on the pump.
The necessary oil is supplied in a can beside the pump.
1.7
Mounting orientation and storage
1.7.1
Mounting orientation :
See required space on chart in paragraph 1.4. Pumps which have been filled with
operating oil must only be moved in the upright position (horizontally). Other-
wise oil may escape. The angle of slope may not be over 10° max. Avoid any
other orientations while moving the pump.
1.7.2
Storage
Before stocking the pump for a long time put it back in its original condition
(blank off inlet and exhaust ports with the shipping seals, drain the oil sump) and
store the pump in a dry place at room temperature. A storage period excee-
ding one year requires a pump maintenance. Please contact Oerlikon Leybold
Vacuum's customer service.
Storage temp. : - 15°C to + 60°C.
1.8
Lubricants
The SOGEVAC SV28 BI pumps should be run with mineral oils for vacuum pumps
with low viscosity according to ISO category VG32. The Oerlikon Leybold Vacuum
oil GS32 corresponds to these prescriptions.
GS32 Oil
Conditioning
Reference
1l
711 17 772
2l
711 17 723
5l
711 17 724
20l
711 17 725
You may use other special lubricants adapted to the applications.
Please consult us.
2
Installation (see chapter 1.1)
It is essential to observe the following instructions step by step to ensure safe
start-up. Start-up may only be conducted by trained specialists.
2.1
Setting-up
The pump must be set up or mounted horizontally on a flat surface. Special
mounting is not required.
The following ambient operating environment must be observed :
. Ambient temperature: 15°C to 40°C (59°F to 104°F),
. Ambient pressure = Atmospheric pressure.
In order to avoid over-heating of the pump, an undisturbed fresh airflow to the
pump is necessary.
GA02331_002_01 - 09/2007 - © Oerlikon Leybold Vacuum
Summary of Contents for Sogevac SV28 BI
Page 6: ...General Instructions GA02331_002_01 09 2007 Oerlikon Leybold Vacuum ...
Page 14: ... 14 GA02330_002_01 09 2007 Oerlikon Leybold Vacuum ...
Page 16: ...Spare parts list 16 GA02331_002_01 09 2007 Oerlikon Leybold Vacuum ...
Page 19: ...Notes 19 GA02331_002_01 09 2007 Oerlikon Leybold Vacuum ...