8
GA02319_002_03 - 07/2007 - © Oerlikon Leybold Vacuum
Description
SV630 BF
Technical data
50 Hz
60 Hz
Pumping speed
1)
m
3
. h
-1
640
755
Ultimate partial pressure
mbar
≤ 8.10
-2
≤ 8.10
-2
without gas ballast
1)
Ultimate total pressure
mbar
≤ 0,7
≤ 0,7
with 1 gas ballast EM
1)
24 VDC
Ultimate total pressure
mbar
≤ 2
≤ 2
with 2 gas ballasts EM
1)
24 VDC
Antisuckback valve 24 VDC
YES
YES
Water vapour tolerance:
mbar
■
without gas ballast
■
with 1 gas ballast
3)
25
30
■
with 2 gas ballasts
3)
35
40
Water vapour capacity:
kg.h
-1
■
without gas ballast
■
with 1 gas ballast
1) 3)
11
14
■
with 2 gas ballasts
1) 3)
15
19
Cooling
H
2
O
H
2
O
Thermostatic valve
YES
YES
Water quality
TH (°F)
4 - 8
4 - 8
Water pressure min./max.
bar
2/8
2/8
see § 3.2 for water consumption
Noise level
2)
dB (A)
72
75
Type of protection/Isolation
IP 54/F
IP 54/F
Rated rotational speed pump
min
-1
820
1000
Weight (with oil filling)
kg
650
650
Oil capacity min./max.
l
20/23
20/23
Thermal switch pump
YES
YES
Thermal switch motor
YES
YES
1) to DIN 28400 and following numbers, with standard gas-ballast
2) operated at the ultime pressure without gas-ballast, free-field measurement at a distance of 1 m
3) please contact Oerlikon Leybold Vacuum
Summary of Contents for 960 862
Page 17: ...17 GA02319_002_03 07 2007 Oerlikon Leybold Vacuum Description fig 4 ...
Page 43: ...43 GA02319_002_03 07 2007 Oerlikon Leybold Vacuum Spare parts DIRECTION OF ROTATION fig 10 ...
Page 44: ...44 GA02319_002_03 07 2007 Oerlikon Leybold Vacuum Spare parts DIRECTION OF ROTATION fig 11 ...
Page 45: ...45 GA02319_002_03 07 2007 Oerlikon Leybold Vacuum Spare parts fig 12 ...
Page 46: ...46 GA02319_002_03 07 2007 Oerlikon Leybold Vacuum Spare parts fig 13 ...
Page 47: ...47 GA02319_002_03 07 2007 Oerlikon Leybold Vacuum Spare parts fig 14 ...
Page 52: ...52 GA02319_002_03 07 2007 Oerlikon Leybold Vacuum ...
Page 54: ...54 GA02319_002_03 07 2007 Oerlikon Leybold Vacuum Notes ...
Page 55: ...55 GA02319_002_03 07 2007 Oerlikon Leybold Vacuum Notes ...