Appendix
OPM223/253
98
C07-OPM2x3xx-13-06-00-en-003.eps
R
Function group
RELAY
Select contact to be
configured
; Rel2; Rel3; Rel4;
Rel1
R1
R2 (6)
R2 (5)
R2 (4)
R2 (3)
R2 (2)
R2 (1)
Function
switch off or on
; on
R2 (2)
off
R221
Enter switch-on
temperature
150.0 °C
-50.0...+150.0°C
R222
Enter switch-off
temperature
150.0 °C
-50.0...+150.0°C
Enter pick-up delay
0...2000 s
0 s
R224
R223
Function
switch off or on
; on; basic; PID+B
R2 (3)
off
R231
Enter set point
; -2.00...16.00 pH
; -1500...1500 mV
; 0...100.0 %
pH 16.00
1500 mV
100.0 %
R232
Enter control
gain Kp
0.01...20.00
1.00
R233
Enter integral action time
Tn (0.0 = no I component)
0.0 min
0.0...999.9 min
R234
Function
switch off or on
; on
R2 (4)
off
R241
Set rinse time
0...999 s
30 s
R242
Set pause time
1...7200 min
360 min
Set minimum pause
time
1...3600 min
120 min
R243
R244
Function
switch off or on
; on
R2 (1)
off
R211
Select contact switch-on
point
; -2.00...16.00 pH
; -1500...1500 mV
; 0...100.0 %
16.00 pH
1500 mV
100.0 %
R212
Select contact switch-off
point
; pH -2.00...16.00
; -1500...1500 mV
; 0...100.0 %
pH 16.00
1500 mV
100.0 %
R213
Enter pick-up delay
0...2000 s
0 s
R214
Enter integral action time
Tn (0.0 = no I component)
0.0...999.9 min
0.0 min
R264
Function
switch off or on
; on
R2 (6)
off
R261
R262
R263
Set point 1 (or 2)
-2.00...16.00 pH
6.00 pH
Enter control
gain Kp1 (or Kp2)
0.01...20.00
1.00
Function
switch off or on
; on
R2 (5)
off
R251
Enter pre-rinse time
0...999 s
30 s
R253
Enter cleaning time
0...999 s
10 s
R254
Select start pulse
;
ext = external;
i+ext = inexternal;
i+stp = internal,
suppressed by ext
int = internal
R252
Limit contactor
configuration
Neutr =
neutralisation controller
(with Rel1 and Rel2
and A1 = pH only)
Clean =
Chemoclean
(with Rel3 only)
Timer
PID controller
LC °C =
Limit contactor T
LC PV =
Limit contactor
pH/Redox
Function group
SERVICE
S
Select language
; GER
ITA; FRA
ESP; NEL
ENG
S1
Hold configuration
s+c=during setup and
calibration
CAL=during calibration
Setup=during setup
none=no hold
S2
Software version
SW version
E111
Hardware version
HW version
E112
Serial number
is displayed
E113
E114
Software version
SW version
E121
Hardware version
HW version
E122
Serial number
is displayed
E123
E124
Software version
SW version
E131
Hardware version
HW version
E132
Serial number
is displayed
E133
E134
Software version
SW version
E141
Hardware version
HW version
E142
Serial number
is displayed
Module name
is displayed
Module name
is displayed
Module name
is displayed
Module name
is displayed
E143
E144
Enter hold
dwell period
0...999 s
10 s
S4
Manual hold
; on
off
S3
Enter release code
for SW upgrade
(Plus package)
0000...9999
0000
S5
Enter release code for
SW upgrade
ChemoClean
0000...9999
0000
S6
Function group
INTERFACE
I
F
unction group
SERVICE 2
E
Enter address
HART: ...15
or PROFIBUS 1...
0
126
Tag is displayed
@@@@@@@@
Select module
Rel = relay
MainB =
mainboard
Trans =
transmitter
Contr = controller
I1
I2
E1(4)
E1(3)
E1(2)
E1(1)
Function group
CHECK
P
SCS alarm
Measuring sensor
; on
off
P1
SCS alarm
Reference sensor
(if A2=sym)
; on
off
P2
Leakage current is
displayed
(ISFET sensors only)
0.0 … 9.9 mA
Alarm delay
0 … 2000 min (s)
0 min (s)
P4
P6
SCS alarm threshold
W
1.5...50 kW
50 k
Select process
monitoring
; Low; High;
LoHi; Lo!; Hi!; LoHi!
Off
P3
P5
Summary of Contents for OPM223
Page 2: ......
Page 95: ...OPM223 253 Technical data 95...
Page 100: ...Appendix OPM223 253 100...
Page 103: ...OPM223 253 103...
Page 104: ...BA194e 00 07 09 71106576 Printed in Germany FM SGML 6 0 DT 71106576...