3.2 Engine Controller-Operating Cont.
Engine must undergo a
60 deg warmup
before clutch switch is live (active/useable)
Must Engage AND Disengage
UNDER 1300rpms
, anything over 1300 will not engage or
disengage
Menu Navigation
1) Press MENU button to scroll available menus
2) Press UP button to enter into a menu
3) Press DOWN button to exit a menu
Change a Menu Setting (Controller Setup menu)
1) A password is required to change a setting
2) Press ENTER button (A bracket appears around the setting)
3) Press the UP and DOWN buttons to view available selections
4) Press ENTER button to make selection, (brackets disappear)
5) Exit menus (hold down MENU button and simultaneously press the ENTER button)
6) RECYCLE POWER TO THE PANEL (Turn panel power off and then back on)
Summary of Contents for DCL800TM
Page 35: ...35 ODB Company DCL800TM ...
Page 36: ...36 ODB Company DCL800TM ...
Page 37: ...37 ODB Company DCL800TM ...
Page 78: ...78 ODB Company DCL800TM 5 10 4 Trailer Bed Wiring Harnesses Diagram Exploded Views Follow ...
Page 79: ...79 ODB Company DCL800TM 5 10 5 Chassis Wiring Harness Diagram ...
Page 80: ...80 ODB Company DCL800TM 5 10 6 Brake Wiring Harness Diagram ...
Page 81: ...81 ODB Company DCL800TM 5 10 7 Bed Wiring Harness Diagram ...
Page 82: ...82 ODB Company DCL800TM 5 10 8 Box Wiring Harness Diagram ...
Page 85: ...85 ODB Company DCL800TM 5 10 11 Remote Throttle Clutch Wiring Harness ...
Page 87: ...87 ODB Company DCL800TM 5 20 1 Hoist Hydraulic System 14 and 20CY ...
Page 88: ...88 ODB Company DCL800TM 5 20 2 Hoist Hydraulic System 25 and 30CY ...
Page 89: ...89 ODB Company DCL800TM 5 20 3 Hoist Hydraulic System with Parking Jack ...
Page 98: ...98 ODB Company DCL800TM 6 7 Kubota Common Service Kubota Engines ...
Page 99: ...99 ODB Company DCL800TM 6 8 Kubota Sheet Metal Group Kubota Engines ...
Page 100: ...100 ODB Company DCL800TM 6 9 Kubota Air Cleaner Group Kubota Engines ...
Page 101: ...101 ODB Company DCL800TM 6 10 Kubota Exhuast Component Group Kubota Engines ...
Page 110: ...110 ODB Company DCL800TM 7 5 Kraft Fluid Drive Group Optional Fluid Drive Coupler Optional ...
Page 144: ...144 ODB Company DCL800TM ...