EX Series Operating Manual
1. General Information
1-1. Feature
EX Series Single Output products are high-performance and high-efficiency programmable DC power
supply with RS232C, RS485, USB, TCP/IP(option) interface based on SCPI (Standard Commands for
Programmable Instruments) protocol and the combination of bench-top and system features in these
Programmable Instruments) protocol and the combination of bench-top and system features in these
power supplies provides versatile solutions for your design and test requirements in the industiral fields,
R&D institute center and education fields.
General Feature
▌Easy-to-use knob control settings.
▌1-Line * big size 16Character LCD Display.
`
▌Output ON/OFF key.
▌F
t
l k
l
k f
ti
▌Front panel key lock function.
▌Alarm beep when events occure.
▌Excellent precision and high resolution.
▌Built-in Remote Sensing for Load Voltage(V-Sensing)
▌O.V.P(Over Voltage Protection) / O.C.P(Over Current Protection) mode supplied.
▌U.V.L(Voltage under level)/O.V.L(Voltage over level) level value setting function.
▌U.C.L(Current under level)/O.C.L(Current over level) level value setting function.
▌E
ll
t l
d
d li
l ti
▌Excellent load and line regulation.
▌Memory(operating state of voltage, current, OVP,OCP) store and recall available up to 10
▌Save and confirm up to 10 error messages.
▌19inch Rack Compact Size(600~2.5KW-1U, 2.5~5KW-2U, 5~10KW-4U)
▌High-efficient output of 80%~90%.
Remote Interface characteristics
▌Supply various interface.(RS232C, RS485, USB, TCP/IP(option))
▌Supply various interface.(RS232C, RS485, USB, TCP/IP(option))
▌adoptend SCPI(Standard Commands for Programmable Instruments) command.
▌High speed setting & measurement
▌Programmed in abundant commands in the instrument.
▌Easy interface setting by front panel key of "I/O config".
▌Technical realization of products insulation & Floating Logic.
▌Buint-in the checking of SCPI programming grammer error.
Calibration
Calibration
▌No need of opening cover of instrument in other to calibrate and adopted software calibration
(by manual and PC).
▌Easy calibration operating by using independence or PC interface.
Factory Function
▌Initial function of 10 user memory.
▌Last state(before turn off the power) memory store and recall function.(state of output ON/OFF,
voltage & current value and etc)
▌The function of "Auto Key Lock & Auto Cursor Move" that prevents operator's mistake.
▌OVP & OCP disable or disable setting function.
▌LCD display speed control function of V/I value by using "ADC(Analog to Digital Conversion)
Sampling" function.
▌Calibration restore function.
▌Calibration backup function.
- 10 -