![Ochsner OTE 3 Operating Instructions Manual Download Page 23](http://html1.mh-extra.com/html/ochsner/ote-3/ote-3_operating-instructions-manual_723515023.webp)
BA_OTE 3+4_Endkunde_EN_V03_20170726.docx
Page 23 of 52
6.5
Set hot water temperature
3 set temperatures can be set for each hot water circuit.
Set values
Description
05-051 Normal setpoint DHW temperature
The desired hot water temperature is set
here.
05-004 Legionella protection temperature
The legionella protection temperature is
set here.
05-086 Economy setpoint DHW temperature
The hot water set-back temperature is set
here.
Settings procedure:
1.
Press
the adjustment knob in the main
display > the main menu appears
2.
Select the Hot water circuit in the main
menu
3.
In hot water circuit temperature image,
select the hot water circuit menu by
pressing
the adjustment knob.
4.
By
turning
the adjustment knob, select
settings
in the main menu and confirm
this by
pressing
the knob.
5.
Select
Setpoint
and confirm by
pressing
the adjustment knob
6.
Select
Normal setpoint DHW temperature
by pressing the settings knob and cali-
brate.
7.
Change/adjust the parameter by
turning
the adjustment knob and store this by
pressing
. By repeated pressing of the ESC
– knob you return to the main display.
05-051
HOT WATER
Normal setpoint DHW
temperature
50.0 °C
ESC
ESC
ENTER
05-086
Economy setpoin 10
HOT WATER
05-051
Normal setpoint 50.0
05-004
Legionella prot 60.0
HOT WATER
Time programm
Setpoint
Configuration
ESC
ENTER
HOT WATER
Operation mode
Operational data
Settings
Relay test
ESC
ENTER
ESC
MENU
HOT WATER
HEAT PUMP
ESC
ENTER
Main menu
HEATING CIRCUIT 1
HEATING CIRCUIT 2
HOT WATER
Heating m ode
OCHSNER OTE
MENU
Sa 05.08.2017
08:10
1
2
3
4
7
5
6