20
www.ochsner.com | OTS_EN
Heating circuit
Note
If it is clear that the room temperature does not
correspond to your required temperature, espe-
cially at higher or lower outdoor temperatures, we
recommend adjusting the heating curve or cooling
curve accordingly. (See page 23, Weather-com-
Note
A change in the target room temperature also
changes the energy consumption of the heat pump
system.
11.2 Operating program
You can switch between several operating programs for
each heating circuit.
Operating program
Description
OFF
The heating circuit is switched off.
Text on the main
screen
Text background
colour
OFF
Red
Frost protection remains active. (See page
COMFORT
Text on the main
screen
Text background
colour
COMFORT
Red
Control takes place with automatic
changeover between heating mode and
cooling mode. A time program can be set
which automatically switches between the
standard target value and the reduced
target value.
NORMAL MODE
This operating program can only be
viewed and set via the menu. In this op-
erating program, none of the operating
program options are shown in red on the
main screen.
Control takes place with automatic
changeover between heating mode and
cooling mode. Control takes place without
a time program. The temperature is always
regulated to the standard target value.
REDUCED
This operating program can only be
viewed and set via the menu. In this op-
erating program, none of the operating
program options are shown in red on the
main screen.
Control takes place with automatic
changeover between heating mode and
cooling mode. Control takes place without
a time program. The temperature is always
regulated to the reduced target value.
11.2.1
Switching the heating circuit on/off
Via the main screen, you can choose between the following
options for each heating circuit:
►
OFF
►
COMFORT
1
Heating circuit switched off
2 Comfort mode
Switching off the heating circuit may make sense to en
-
sure that no heating or cooling takes place in spring and
autumn, when there may be large temperature fluctuations
between day and night. In general however, heating/cool-
ing limits and building inertia should be adjusted correctly
and thus take over this function.
Note
If you want to switch off a heating circuit, use the
operating program of the relevant heating circuit.
Do not disconnect the heat pump from the power
supply.
The Comfort program is the default operating program of
the heating circuit. In this mode, a time program can be
used. (See page 35, Time program)
Summary of Contents for AIR FALCON 212
Page 7: ...BA 982018 AIR FALCON sh EN www ochsner com 7...
Page 9: ...00_400_200_202_01_split_Funktionsweise EN www ochsner com 9 How split systems work...
Page 65: ...OTS_EN www ochsner com 65 Expert mode...
Page 77: ...OTS_ZSM_EN www ochsner com 77...
Page 85: ...BA 982018 AIR FALCON EN07 www ochsner com 85...
Page 86: ...Notes...
Page 87: ...Notes...