DHW circuit
Description
Unit
Standard
cooling
The heating circuit is in cooling mode.
The temperature is regulated to the
target value: Target room temperature
standard cooling
Defrost
The heat pump is in defrosting mode.
Hot water pri-
ority
The heating circuit is switched off for
the duration of DHW heating.
Maximum
temperature
shutdown
The heating circuit is switched off to
protect your system as the flow temper-
ature is too high.
Dew point
shutdown
The heating circuit is switched off as
the dew point limit was undershot.
Emergency
mode
The heat pump is in emergency mode
and can no longer be operated.
Heat is generated via the electric aux-
iliary heater. This can result in higher
running costs.
(See page 48, Emergency mode)
Forced throt-
tling
This operation status only occurs if a
buffer tank is installed:
The buffer tank temperature deviates
from the temperature requested by
the heating circuit. The heating circuit
pump was temporarily shut down.
This prevents the heating circuit from
cooling down in heating mode.
This prevents the cooling circuit from
heating up in cooling mode.
The heating circuit pump is started
again when the required temperature is
reached in the buffer tank.
Outdoor temper-
ature
The current outdoor temperature is dis-
played here.
°C
Average outdoor
temperature
The average outdoor temperature used
for the heating and cooling curve is dis-
played here.
°C
Room temper-
ature
The room temperature of the heating
circuit measured by the room tempera-
ture sensor is displayed here. If there is
no room temperature sensor, this oper-
ating data does not appear.
°C
Relative humidity
The relative humidity of the heating
circuit measured by the room sensor
is displayed here. If there is no room
sensor, this operating data does not
appear.
%
Dew point tem-
perature
The dew point temperature calculated
by the controller is displayed here.
°C
Target room tem-
perature heating
The current target value in heating
mode is displayed here.
°C
Target room tem-
perature cooling
The current target value in cooling
mode is displayed here.
°C
Flow temperature
heating circuit
The actual flow temperature of the
heating circuit is displayed here.
°C
Target flow tem-
perature, heating
circuit
The target value calculated for the flow
temperature of the heating circuit is
displayed here.
°C
Heating circuit
pump
Here you can see whether or not the
heating circulation pump is running.
-
Mixing valve heat-
ing circuit
The opening degree of the mixing valve
is displayed here in %.
%
Mixing valve heat-
ing circuit open
If the opening degree of the mixing
valve is extended, then ON is displayed
here.
-
Mixing valve heat-
ing circuit closed
If the opening degree of the mixing
valve is reduced, then ON is displayed
here.
-
11.9.1 Viewing operating data
»
Open the menu.
»
Select the heating circuit for which you want to view
the operating data.
»
Select “Operating data”.
12. DHW circuit
DHW heating takes precedence over heating and cooling
mode. During DHW heating, the heating circulation pumps
are switched off, subject to system type and controller set
-
ting.
DHW heating is active if:
►
There is a heat demand
►
At least 1 heat generator is active
►
No outage or fault is present
►
No electricity tariff shutdown has occurred
A heat demand exists if the current DHW temperature on
the DHW temperature sensor is lower than the DHW target
temperature by the set switching differential.
1 Set target value
2
Set switching differential
3 Current temperature at temperature sensor
4 Heat demand
12.1 Setting the DHW temperature
The target DHW temperature can be adjusted directly on
the main screen of the respective DHW circuit.
»
Open the main screen of the DHW circuit for which
you want to change the temperature.
»
Press the plus or minus button to adjust the target
DHW temperature.
Summary of Contents for AIR FALCON 212
Page 7: ...BA 982018 AIR FALCON sh EN www ochsner com 7...
Page 9: ...00_400_200_202_01_split_Funktionsweise EN www ochsner com 9 How split systems work...
Page 65: ...OTS_EN www ochsner com 65 Expert mode...
Page 77: ...OTS_ZSM_EN www ochsner com 77...
Page 85: ...BA 982018 AIR FALCON EN07 www ochsner com 85...
Page 86: ...Notes...
Page 87: ...Notes...