Appliance installation
Material damage
When the appliance casing has been dismantled,
sensitive components are fully exposed.
»
Assemble the appliance casing as soon as
there is nothing more that needs to be done
inside the appliance.
»
During the building phase, provide the appli-
ance with additional protection from dirt and
dust with a suitable covering.
9.1.4 Assembling the appliance casing
Install the appliance casing in reverse order.
9.1.5 Separating the appliance sections
»
Pull out the heating sensor from the buffer tank.
»
Remove the sensor cable from the guiding groove in
the insulation element.
1 Heating sensor
2 Sensor sleeve
3 Guide groove
»
Undo the plug-in connectors of the 4 hydraulic
connections. Pull out the spring clips fully using a
screwdriver.
»
Pull off the hydraulic connections towards the front.
»
Remove the 4 hydraulic hoses and the thermal insula-
tion element.