BA_OCHSNER AIR EAGLE_414_717_V06_EN.docx
Page 19 of 76
4.2 T200 (MULTI TOWER) indoor unit
Appliance description
The buffer tank and the DHW tank with heat
exchanger are arranged on top of each other and
can be separated for handling.
1
Heat pump
2
Hot gas
3
Liquid
4
Buffer charging pump
5
Multifunctional assembly (MFA)
6
Magnesium anode
7
Cable grommet
8
Drain stopcock
9
Heating circuit
10
DHW circulation
11
Cold water
12
DHW
13
Connecting hoses
14
Buffer tank
15
DHW tank
Figure 21:
T200 hydraulic schematic
The appliance is fitted with a plastic foam outer
casing and a removable front panel. The appliance
is connected hydraulically and electrically to the
heat pump. All hydraulic connections are at the
top.
Further system components are integrated
alongside the DHW tank and the buffer tank:
Heat pump manager, tank charging pump, high
efficiency circulation pump for one direct heating
circuit, multifunctional assembly with safety valve
and 3-way switching valve, emergency/booster
heater for mono energetic operation.
4.2.1.1 DHW tank
The steel tank is fitted internally with a special
direct enamel and a sacrificial anode. The anode
with wear indicator protects the inside of the tank
against corrosion.
The heating water heated by the heat pump is
pumped through an internal indirect coil in the
DHW tank. The internal indirect coil transfers the
absorbed heat to the DHW. The integral heat
pump manager controls DHW heating to the
required temperature.
4.2.1.2 Buffer tank
The steel tank serves to hydraulically separate the
flow rates of the heat pump and the heating
circuit. The heating water heated by the heat
pump is transported to the buffer tank by the tank
charging pump. When there is a demand, the
heating water is supplied to the heating circuit by
the integral heating circuit circulation pump.
4.2.1.3 Heat pump manager (OTE)
The system is controlled via the integral OTE3 heat
pump manager. For adjustment options, see the
controller operating manual.
4.2.1.4 Multifunctional assembly (MFA)
The multifunctional assembly switches between
heating circuit and DHW heating.
10 11 12
9
2
1
3
5
6
8
7
13
8
4
14
15
Summary of Contents for Air Eagle 414
Page 2: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 2 of 76...
Page 63: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 63 of 76...
Page 64: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 64 of 76...
Page 65: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 65 of 76...
Page 66: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 66 of 76...
Page 68: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 68 of 76...
Page 69: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 69 of 76...
Page 70: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 70 of 76...
Page 71: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 71 of 76...
Page 73: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 73 of 76 16 Declaration of conformity...
Page 74: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 74 of 76...
Page 75: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 75 of 76...