11 Maintenance
For maintenance work, disconnect the
power supply to the indoor unit and
the outdoor unit of your heat pump.
NOTE
Ensure that the refrigerant circuit of
your heat pump is tested for leaks once
a year (in acc. with Regulation
(EU) no. 517/2014).
-
Ensure
year-round
access
to
soldered joints in the refrigerant
circuit.
-
Document the results of the
leakage test in the system test
report.
We recommend arranging for an inspection and if
necessary a service on the heat pump to be
conducted once a year. We draw your attention to
the fact that statutory regulations require regular
testing of heating systems by the system user.
The refrigerants used in OCHSNER heat pumps are
non-flammable, non-toxic and ozone neutral.
However,
heat
pumps
are
refrigeration
equipment and are subject to the provisions of the
F-gas Regulations (Regulation (EU) no. 517/2014).
OCHSNER Customer Service will be pleased to help
in carrying out maintenance and testing, in
particular as required by the F-gas Regulations.
For
more information, see
www.ochsner.com
.
We recommend testing the heating water system
pressure and correcting it if necessary (pressure
too high/low).
We recommend adjusting the pre-charge pressure
in the diaphragm expansion vessel (DEV) on the
system accordingly (system height).
We recommend monitoring the flow rate of the
heat sink system (WNA) and if necessary the heat
source system (WQA) using the flow meters
specified by OCHSNER.
We recommend that when non-routine work
takes place requiring refilling (e.g. system
alteration or pipe breakage), a current water
assessment be prepared and the heat sink system
be refilled on the basis of this.
11.1 Customer service
Once a date has been agreed with or requested
from OCHSNER customer service, repairs to your
heat pump are carried out by a trained customer
service specialist on site. In order for service work
to be carried out, the accessibility of the heat
pump and auxiliary equipment must be ensured at
all times!
Please
observe
the
minimum
clearances
when
installing
the
equipment.
Customer Service hotline for Austria:
Tel:
+43 (0) 504245
–
499
Email:
Customer Service hotline for Germany:
Tel:
+49 (0) 69 256694 - 495
Email:
Customer Service hotline for Switzerland:
Tel:
+41 (0) 800 100 911
Email:
Summary of Contents for Air Eagle 414
Page 2: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 2 of 76...
Page 63: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 63 of 76...
Page 64: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 64 of 76...
Page 65: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 65 of 76...
Page 66: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 66 of 76...
Page 68: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 68 of 76...
Page 69: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 69 of 76...
Page 70: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 70 of 76...
Page 71: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 71 of 76...
Page 73: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 73 of 76 16 Declaration of conformity...
Page 74: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 74 of 76...
Page 75: ...BA_OCHSNER AIR EAGLE_414_717_V06_EN docx Page 75 of 76...