Chart 12
Trouble description
Cause
Solutions
There is no display on the
control panel when the on/off
switch is pressed
There is a problem with;
1.Power supply or
2. Circuit board transformer or
3. Fuse
1. Chck the power supply. If
the power supply indicator
LED L1 (red) is on check the
wire.
2. Change the controller
The controller is on but the
sauna heater doesn’t work
1 .The sauna heater hasn’t
been connected
2. There is a problem with the
controller
1. Check the connection, refer
to page 6, 7 and 14.
2. Change the controller
OverHeat LED is on
1. The temperature sensor
hasn’t been connected
correctly
2. The high tempeature cut off
switch is turned off
1. Check the connection to the
temperature sensor.
2. Check if the high
temperature cut off switch is
turned off, i yes, reset by hand
Door LED is on
During the advance timer
countdown sequence ,the
sauna room door has been
opened , the timing stopped
and will not restart again until
it is reset.
Reset counter down timer
Wait LED is on red
Sauna heater is under B mode Press the Mode button to
change to A mode (heating
Mode)
Temperature windows display
- - L
o
or - -H
o
1. Thermometer isn’t
connected or cable is broken
2. The temperature is lower
than 0
o
C .
3. The temperature is higher
than 115
o
C
1. -- L
o
C means temperature
sensor hasn’t connected or the
temperature is lower than 0
o
C
check the connection, cable or
change sensor
2. --H
o
C means there is a short
circuit in the temperature
sensor or the temperature is
higher than 115
o
C check the
connection,cable or change
sensor.
3.Change controller.