Sauna & Steam
Oceanic Saunas 01902 450 550 sales
@oceanic-saunas.co.uk www.oceanic-saunas.co.uk
18
Sauna Heater Manual
above the heater
3. Exhaust air vent
4. Drying vent, which is closed during heating and bathing, the sauna room can also be dried by
leaving the door open after bathing
5. If there is only an exhaust vent in washing room, leave an opening (MIN 1CM). Under the
sauna door (Mechanical ventilation is recommended in the outside room)
11. Testing and Operation
11.1. Testing
•
Before connecting to the power supply check the sauna heater and make sure there are
no flammable items on or around the heater, please note that on the first use the elements and
stones may smoke slightly and give off a smell – please ensure the sauna cabin is well ventilated.
•
Connect to power supply, press “ “key, temp and time windows will display data, LED
shows the sauna’s heating status when the light is on, the temperature of sauna room will rise and
will achieve the preset temperature (the default settings are 70
o
C/158
o
F, work time is 2 hours)
Chart 10
11.2. Setting time and temperature:
•
The default settings for temperature are: 75
o
C/167
o
F. For preset operation time: 2 hours.
Fig 14
Model
Default Mode
Default Temp
o
C/
o
F
Temperature adjust scope
o
C
OC-SB
A
75
o
C
187
o
F
50-110
o
C
122-230
o
F
Default Time
Time adjust scope
Working time
Waiting
Work time
Wait time
2hrs
4hrs
10mins - 8hrs
0-12 hrs
Time adjustment per button press
Temperature adjustment per button
press
10 mins
1
o
C /2
o
F