Operation and Upkeep
29
Camera out-of-light error
If the
Call Service
and
Warm-Up
indicators start blinking together on the
scanner Control Panel, one of the cameras has moved out of range during
adjustment or transport and then it does not receive enough light.
The Warm-up indicator shows by the number of flashes per second which
camera is out of light:
Camera 1
1 flash per second
Camera 2
2 flashes per second
Camera 3
3 flashes per second
Before adjusting the camera height, carry out the following procedure:
1
Turn the height adjustment complete anti-clockwise.
2
Turn the height adjustment one quarter of a turn clockwise.
3
Turn the scanner power off and then on. If the error still occurs repeat steps 2
and 3.
After clearing the "Camera out of light error", proceed with the Camera height
adjustment described previously.