OMC-140 Installation Manual
Page 58
15 Menu Structure Terminal Mode
Main Menu:
1
Device Settings
1 Display Intensity (ON)
1 ON
2 OFF
3 NMEA DDC
2 Sensor 1
Installation Settings Sensor 1:
Watchdog Time
1 Baud rate (4800)
1 4800
2 9600
3 19200
2 Watchdog
(OFF)
3 MWV Relative
(ON) ( 10) sec
Turn MWV Relative message (2) AUTO / (1) ON / (0) OFF: 1
Watchdog time in seconds (No value = 10 sec):
4 MWV Theoretical
(AUTO)
5 MWD True
(AUTO)
6 GGA GPS Quality
(AUTO)
7 VTG GPS Ship Heading
(AUTO)
8 HDT/THS Gyro Heading
(AUTO)
9 VHW Log Speed
(AUTO)
A XDR Data
(AUTO)
B GMP GPS Data
(AUTO)
C GST GPS Data
(AUTO)
D MHU Humidity Data
(AUTO)
E MMB Baro Data
(AUTO)
F MTA Air Temp. Data
(AUTO)
G MDA Combined Data
(AUTO)
H MTW Water Temp. Data
(AUTO)
I VIS Visibility Data
(AUTO)
J CME Cloud Data
(AUTO)
K BTD Lightning Data
(AUTO)
L DBK Depth Data
(AUTO)
M DPT Depth Data
(AUTO)
N VLW Water Distance
(AUTO)
O VBW Water Speed
(AUTO)
P ROT Rate Of Turn
(AUTO)
Q Baro Status
(AUTO)
Z NMEA Allow No Checksum (OFF) Port 1 & 2
0 Previous Menu
3 Sensor 2
installation Settings Sensor 2:
Watchdog Time
1 Baud rate (4800)
Summary of Contents for OMC-140
Page 5: ...OMC 140 Installation Manual Page 5 Page intentionally left blank ...
Page 31: ...OMC 140 Installation Manual Page 31 Repeat this for the other sensors if any ...
Page 51: ...OMC 140 Installation Manual Page 51 Observator Proprietary Messages POBSBTD POBSCBE POBSVIS ...
Page 65: ...OMC 140 Installation Manual Page 65 16 Dimensional drawings ...
Page 68: ...OMC 140 Installation Manual Page 68 17 3 Optional Keypad panel cut out ...