OMC-140 Installation Manual
Page 14
5.3 AC Power Connection
The standard OMC-140 Display accepts AC voltages in the range of 100 .. 240VAC @ 45 ..
65 Hz.
The connection is meant for panel mount installations.
For AC power a green connector is used.
Note: For installations where the AC Mains connection is accessible the optional connector cover
must be installed!
5.4 DC power connection
Optional the display can be delivered suitable for 24VDC.
It has a different power supply not suitable for AC power!
The DC power connecter is black.
The display is marked to be suitable for DC power (18 .. 32VDC)
5.5 DC power module connections (optional)
Optional the AC version of the OMC-140 display can be supplied with a DC power module.
This enables the display to be powered by both AC and DC power.
Useful if backup power is required.
Due to the wide range of the DC input it also allows the display to run on 12VDC.
DC power
1
GND
2
Power +9
…+30VDC
Summary of Contents for OMC-140
Page 5: ...OMC 140 Installation Manual Page 5 Page intentionally left blank ...
Page 31: ...OMC 140 Installation Manual Page 31 Repeat this for the other sensors if any ...
Page 51: ...OMC 140 Installation Manual Page 51 Observator Proprietary Messages POBSBTD POBSCBE POBSVIS ...
Page 65: ...OMC 140 Installation Manual Page 65 16 Dimensional drawings ...
Page 68: ...OMC 140 Installation Manual Page 68 17 3 Optional Keypad panel cut out ...