Section 3: Freestanding Stove (cont.)

Installation of legs or Pedestal & First Pipe Segment

1. 

Remove firebrick and all other items inside stove.

2. 

Tilt stove on its back.

3. 

Attach legs or pedestal using 3/8” bolts provided. (See Figure 5)

4. 

Tilt stove back into normal position.

5. 

Insert pipe into 8” collar on top of stove.

6. 

Place plugs in the six holes located on the top and both sides by tapping them in 

with a hammer. Replace firebrick.

Stove Pipe Installation

1. 

Minimum clearance to combustibles must be maintained as shown in Figure 4.

2. 

Combustible wall and ceiling materials include wood, cloth, vinyl, paper, etc. Wood 

covered with plastic is also considered combustible. The 24” clearance for the 

stove also applies for plain stovepipe used in constructing the chimney pipe. Clear-

ance is applicable to the parallel wall or from the ceiling either when the wall is un-

protected or when 3/8” insulated millboard is affixed to the wall without spacing.

3. 

Select a spot for the stove. Inspect the area that a stovepipe will be running 

through to connect with the existing chimney, Use an insulated connector if a 

combustible wall is between the chimney and stove.

4. 

If the area the pipe runs through looks acceptable, move the stove into position. 

Be sure the stove had proper clearance from combustible areas.

5. 

If a new chimney is being installed, follow the instructions of the chimney pipe 

manufacturer or have it installed by a certified chimney installer.

6. 

Install the chimney connector-if it is passing through combustible walls, it must be 

insulated such as triple-wall pipe. Also, if it is impossible to maintain 24” between 

your smoke pipe and a combustible wall, use an insulated chimney pipe. Also con-

sult local building codes and regulations. 

7. 

After the pipe connector is in place, run the stovepipe with the crimped edge 

down from the chimney connector to the stove. The crimped edges must be down 

so creosote accumulation on the walls of the stovepipe can run back into the stove 

and not out the joints of the pipe.

8. 

Check installation to determine that the pipe is connected properly using three 

sheet metal screws per joint; that the proper distances have been maintained from 

combustible surfaces with the stove and the stovepipe; and the chimney is in good 

repair and is installed properly.

Section 4: Installation of Blower for Model 2500

After 2500 stove is installed, you will need to install blower on your stove. The blower, 

along with four 1/4” x 20 cap screws, has been placed into the firebox of the stove. 

Please follow steps below to install bower. Blower for Model 1500 is already installed.

1. 

Remove the front blower cover locate the opening for the blower.

2. 

Remove blower package from inside the firebox where it was placed for shipping.

3. 

Place the blower onto the stove with the motor turned down.

4. 

Secure the blower onto the stove using the four 1/4”.20 cap screws.

5. 

Connect the two wires from the blower to the wires on the stove.

6. 

Replace the magnetic blower cover and begin using the stove.

Summary of Contents for 1500

Page 1: ...604 Model 2500 and 1500 Freestanding Stove or Fireplace Insert Safety Notice If this wood stove is not properly installed a house fire may result For your safety please follow the installation directi...

Page 2: ...NOTICE Gold plated surface must be cleaned with glass cleaner and a soft rag before firing the first time or fingerprints will remain...

Page 3: ...or Pedestal Installation of First Pipe Segment Stove Pipe Installation Section 4 Blower Installation Pg 8 Section 5 Additional Safety Precautions Pg 9 Section 6 Operating Building an Efficient Fire Pg...

Page 4: ...tove so top front edge is out in front of opening approx 7 for 1500 and 9 for 2500 If you are using a direct connect with flue pipe be sure to install connect now 2 Remove tape backing from Surround G...

Page 5: ...excellent heat resistance and strength characteristics it can crack through improper use To achieve maximum utility and safety of glass In a wood burning stove we advise the following 1 Inspect the g...

Page 6: ...alley Stoves are tested by Arnold Green Testing Laboratories 6 Huren Drive East Natuck Industrial Park Natuck MA 01760 General Safety Precautions 1 Keep stove away from combustibles Follow suggested d...

Page 7: ...paid to the point where the flu passes through a wall or a ceiling This penetration should always be made with insulated pipe and the proper accessories 13 The longer the pipe and the larger the numbe...

Page 8: ...or have it installed by a certified chimney installer 6 Install the chimney connector if it is passing through combustible walls it must be insulated such as triple wall pipe Also if it is impossible...

Page 9: ...creosote makes an extremely hot fire CAUTION Do not operate the stove to such an extreme that any portion becomes red hot 4 Pre Fabricated Chimney Class A masonry or all fuel pre fabricated chimneys...

Page 10: ...500 F 2 Pull Primary Damper and Under Fire Damper completely open Primary Damper is on right side and Under Fire Damper is on left side pull to open push to close 3 Prepare tinder and kindling by cru...

Page 11: ...rk properly Use smaller dry wood to create a hot fire in the stove Cap could be covering your flue 3 Smoke comes out combustion air holes or air vents Obstruction in the flue Must build a hotter fire...

Page 12: ...Periods Period 1 Up to 30 days after purchase Stove should be used within 30 days by having a fire started the blower and heat generated in the owner s home Period 2 Up to 90 days after purchase All...

Page 13: ...o not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Warranty repairs for reimbursement must be performed by an authorized High Val ley Dealer man...

Page 14: ...14 www woodstoves net Section 9 Wiring Diagrams 2500 Wiring Diagram 1500 Wiring Diagram...

Page 15: ...P Phone Email Stove Was Purchased At Selling Price Less Tax Date Purchased Date Installed Model Purchased select one q 2500 q 1500 q ZC Cabinet ZC Serial Number Wood Stove Serial Number found on rear...

Page 16: ...Place Stamp Here Obadiah s Warranty c o Stoll 153 Hwy 201 Abbeville SC 29620 From...

Page 17: ......

Reviews: