background image

15

800

-968-8604

Owner Registration Card

Name:
Address:
City:   

 

 

 

State:    

ZIP:

Phone:  

 

 

 

Email:

Stove Was Purchased At:
Selling Price Less Tax:
Date Purchased:
Date Installed:
Model Purchased: 

(select one)

 

q

 2500

 

q

 1500

 

q

 ZC Cabinet

ZC Serial Number:
Wood Stove Serial Number:   

  

             

(found on rear of unit)

Remove page from book then fold in half and tape. 

Cut Here

Summary of Contents for 1500

Page 1: ...604 Model 2500 and 1500 Freestanding Stove or Fireplace Insert Safety Notice If this wood stove is not properly installed a house fire may result For your safety please follow the installation directi...

Page 2: ...NOTICE Gold plated surface must be cleaned with glass cleaner and a soft rag before firing the first time or fingerprints will remain...

Page 3: ...or Pedestal Installation of First Pipe Segment Stove Pipe Installation Section 4 Blower Installation Pg 8 Section 5 Additional Safety Precautions Pg 9 Section 6 Operating Building an Efficient Fire Pg...

Page 4: ...tove so top front edge is out in front of opening approx 7 for 1500 and 9 for 2500 If you are using a direct connect with flue pipe be sure to install connect now 2 Remove tape backing from Surround G...

Page 5: ...excellent heat resistance and strength characteristics it can crack through improper use To achieve maximum utility and safety of glass In a wood burning stove we advise the following 1 Inspect the g...

Page 6: ...alley Stoves are tested by Arnold Green Testing Laboratories 6 Huren Drive East Natuck Industrial Park Natuck MA 01760 General Safety Precautions 1 Keep stove away from combustibles Follow suggested d...

Page 7: ...paid to the point where the flu passes through a wall or a ceiling This penetration should always be made with insulated pipe and the proper accessories 13 The longer the pipe and the larger the numbe...

Page 8: ...or have it installed by a certified chimney installer 6 Install the chimney connector if it is passing through combustible walls it must be insulated such as triple wall pipe Also if it is impossible...

Page 9: ...creosote makes an extremely hot fire CAUTION Do not operate the stove to such an extreme that any portion becomes red hot 4 Pre Fabricated Chimney Class A masonry or all fuel pre fabricated chimneys...

Page 10: ...500 F 2 Pull Primary Damper and Under Fire Damper completely open Primary Damper is on right side and Under Fire Damper is on left side pull to open push to close 3 Prepare tinder and kindling by cru...

Page 11: ...rk properly Use smaller dry wood to create a hot fire in the stove Cap could be covering your flue 3 Smoke comes out combustion air holes or air vents Obstruction in the flue Must build a hotter fire...

Page 12: ...Periods Period 1 Up to 30 days after purchase Stove should be used within 30 days by having a fire started the blower and heat generated in the owner s home Period 2 Up to 90 days after purchase All...

Page 13: ...o not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Warranty repairs for reimbursement must be performed by an authorized High Val ley Dealer man...

Page 14: ...14 www woodstoves net Section 9 Wiring Diagrams 2500 Wiring Diagram 1500 Wiring Diagram...

Page 15: ...P Phone Email Stove Was Purchased At Selling Price Less Tax Date Purchased Date Installed Model Purchased select one q 2500 q 1500 q ZC Cabinet ZC Serial Number Wood Stove Serial Number found on rear...

Page 16: ...Place Stamp Here Obadiah s Warranty c o Stoll 153 Hwy 201 Abbeville SC 29620 From...

Page 17: ......