Installing the filter system: 

 

It is recommended that you use a filter system with ¼” push-fit connections for both inlet and 
outlet 

 

Refer to the instructions provided with the filter system prior to installation 

 

Attach the filter system to the metal column support – you can drill holes as required for 
mounting screws 

 

Cut the water supply tube and connect the lower portion to the inlet side of the filter system 
and the upper portion to the outlet side of the filter system 

 
Installing the cooler: 
 

 

EUROPE ONLY 

 

The European Point of Use Water Distribution Association (EPDWA) provides formal Hygiene 

Awareness and Installation training courses. All staff involved in the installation and sanitising of POU 

water coolers for an EPWDA member company must receive this training. 

 

The purpose of this training program is to provide an overview of POU systems offered by OASIS and 

an introduction to the basic guidelines that should be followed when installing an OASIS water cooler 

onto an existing mains water system. 

 

It is recommended that all companies undertake the necessary EPDWA training courses to help maintain 

the professional image of the industry 

 

A documented site survey must be conducted prior to installing a cooler in a facility. Copies of all 

surveys should be held at the installer’s premises. The purpose of the survey is to ensure that the cooler 

is installed in a suitable location. 

 
 
The general installation guidelines below should be followed: 

 

The cooler must be located on a floor that is smooth, level and easily cleaned. 

 

Do not locate the cooler in direct sunlight. 

 

Do not locate the cooler next to a radiator. 

 

Do not locate the cooler within or directly adjacent to toilet facilities. 

 

Do not locate the cooler in constantly damp areas, beneath dripping pipes, or where water may 
collect underfoot. 

 
Examine the proposed cooler location for the following: 

 

Location of electrical supply 

o

 

The cooler should be installed no more than 2 meters (6 feet) from the nearest electrical 
outlet.  

o

 

It should be possible to access the plug when the cooler is in its final position. 

 

Location of potable water supply 

o

 

The cooler must be attached to a potable water source. 

Summary of Contents for P1PV Series

Page 1: ...INSTALLATION SERVICE INSTRUCTIONS P1PV P1PVCD Series Coolers...

Page 2: ...th 345 mm 13 6 in Net Weight 23 kg 51 lbs Filter Compartment Height 560 mm 22 in Width 260 mm 10 2 in Depth 120 mm 4 7 in Electrical Specification P1PVKY P1PVK P1PVHSY P1PVHS P1PVHSKY P1PVHSK P1PVCDKY...

Page 3: ...he water colder and vice versa Ambient Water Circuit The water in the ambient water circuit is not cooled the temperature of the water will be the same as the temperature of the water that comes out o...

Page 4: ...to NSF standards 51 and 61 The machine is connected to the water supply by a female bulkhead fitting The entire internal water circuit and all the components which come in contact with water are food...

Page 5: ...no marks or physical damage to the cooler b All accessories are present c All wires and electrical connections are in place at the back of the cooler d All tubes and water connections are in place e...

Page 6: ...ooler 9 The cooler is now ready for transportation to the customer s premises NOTE Whenever you transport the cooler to or from your premises you should ensure that a shipping bag is placed over the c...

Page 7: ...valve prior to opening it The container needs to have a minimum capacity of 2 litres 2 quarts Re assemble the cooler by following the above instructions in the reverse order Filter Installation The P1...

Page 8: ...followed when installing an OASIS water cooler onto an existing mains water system It is recommended that all companies undertake the necessary EPDWA training courses to help maintain the professiona...

Page 9: ...here they may occur Each cooler should have an independent isolating valve This is intended so that the cooler can be replaced without draining long lengths of piping EUROPE ONLY In accordance with EP...

Page 10: ...damage to the cooler b That all accessories are present c That all the wires and electrical connections are in place at the back of the cooler d That the cooler is clean and dust free e Sit the machin...

Page 11: ...off valve in the filter system is in the Open position Water flows from the ambient or hot system no water flows from cold system o Water within cooling system is frozen Check the thermostat setting t...

Page 12: ...afety Instructions Isolate the water cooler from the water supply this may be done by closing any shut off valve fitted to the installation or temporarily disconnecting the cooler from the water suppl...

Page 13: ...20 034734 002 034734 002 TUBING 3 8 OUTLET VENT Equipment Household bleach 5 sodium hypochlorite Mild soap solution Plastic bucket One 12 length of OD plastic tubing Preparation of Filter Cleaning Ca...

Page 14: ...rd at the rear of the machine Wear clean rubber gloves to carry out the cleaning functions Remove and clean the drip tray assembly Wipe down all machine surfaces with a mild soap solution or mild clea...

Page 15: ...OASIS Corporation Disconnect the blue tube running from the solenoid to the hot tank inlet see figure for location of this tube Thread the blue tubing through the hole in the shelf as shown above as s...

Page 16: ...cooler to the mains supply Drain at least 5 litres of hot water from the outlet before switching on the hot tank THIS APPLIANCE MUST BE EARTHED This appliance is not suitable for unsupervised use by y...

Reviews: