P1PV / P1PVCD Series
Installation & Service Instructions
030099-347 Rev. 2
pg 7 of 16
© Copyright 2007 OASIS Corporation
•
Remove the screw holding the plug in position on the drain valve at the rear of the unit
•
Rotate the plug counter-clockwise and pull from the drain body
•
Allow water to drain from the valve
•
The drain is located 280mm (11 in) from the floor – ensure that you place a container under the
valve prior to opening it. The container needs to have a minimum capacity of 2 litres (2 quarts).
•
Re-assemble the cooler by following the above instructions in the reverse order
Filter Installation:
The P1PV and P1PVCD series coolers contain a large filter compartment that can be directly accessed
from the front of the unit.
Accessing Filter Compartment:
•
Lift out and remove the drip tray
•
Depress the clip visible through the slot in the alcove and lean the top of the door forward
•
Remove the door from the cooler
•
The water supply tube is now visible on the left hand side of the filter compartment