P1PV / P1PVCD Series 

Installation & Service Instructions 

 

 
 

 

 

030099-347 Rev. 2 

pg 12 of 16  

         © Copyright 2007 OASIS Corporation 

Accessing the Internal Chassis 
 

In order to carry out repairs to the refrigeration system, you may need to remove the side panel(s) from 
the cabinet. Please follow the instructions given below to carry out this operation: 
 

Safety Instructions: 

 

Isolate the water cooler from the water supply – this may be done by closing any shut-off valve 
fitted to the installation or temporarily disconnecting the cooler from the water supply. 

 

Disconnect the cooler from the power supply. 

 

Remove Top from the Cooler: 

 

Remove the two screws at the rear of the top, and lift off the lid assembly 

                       

                

 

Remove Side Panel 

 

Remove the three screws as shown 

 

Raise the panel vertically by about 25mm (1”) so that it clears the molded base and the key slot, 
then lift the panel away from the cooler 

 

 

Summary of Contents for P1PV Series

Page 1: ...INSTALLATION SERVICE INSTRUCTIONS P1PV P1PVCD Series Coolers...

Page 2: ...th 345 mm 13 6 in Net Weight 23 kg 51 lbs Filter Compartment Height 560 mm 22 in Width 260 mm 10 2 in Depth 120 mm 4 7 in Electrical Specification P1PVKY P1PVK P1PVHSY P1PVHS P1PVHSKY P1PVHSK P1PVCDKY...

Page 3: ...he water colder and vice versa Ambient Water Circuit The water in the ambient water circuit is not cooled the temperature of the water will be the same as the temperature of the water that comes out o...

Page 4: ...to NSF standards 51 and 61 The machine is connected to the water supply by a female bulkhead fitting The entire internal water circuit and all the components which come in contact with water are food...

Page 5: ...no marks or physical damage to the cooler b All accessories are present c All wires and electrical connections are in place at the back of the cooler d All tubes and water connections are in place e...

Page 6: ...ooler 9 The cooler is now ready for transportation to the customer s premises NOTE Whenever you transport the cooler to or from your premises you should ensure that a shipping bag is placed over the c...

Page 7: ...valve prior to opening it The container needs to have a minimum capacity of 2 litres 2 quarts Re assemble the cooler by following the above instructions in the reverse order Filter Installation The P1...

Page 8: ...followed when installing an OASIS water cooler onto an existing mains water system It is recommended that all companies undertake the necessary EPDWA training courses to help maintain the professiona...

Page 9: ...here they may occur Each cooler should have an independent isolating valve This is intended so that the cooler can be replaced without draining long lengths of piping EUROPE ONLY In accordance with EP...

Page 10: ...damage to the cooler b That all accessories are present c That all the wires and electrical connections are in place at the back of the cooler d That the cooler is clean and dust free e Sit the machin...

Page 11: ...off valve in the filter system is in the Open position Water flows from the ambient or hot system no water flows from cold system o Water within cooling system is frozen Check the thermostat setting t...

Page 12: ...afety Instructions Isolate the water cooler from the water supply this may be done by closing any shut off valve fitted to the installation or temporarily disconnecting the cooler from the water suppl...

Page 13: ...20 034734 002 034734 002 TUBING 3 8 OUTLET VENT Equipment Household bleach 5 sodium hypochlorite Mild soap solution Plastic bucket One 12 length of OD plastic tubing Preparation of Filter Cleaning Ca...

Page 14: ...rd at the rear of the machine Wear clean rubber gloves to carry out the cleaning functions Remove and clean the drip tray assembly Wipe down all machine surfaces with a mild soap solution or mild clea...

Page 15: ...OASIS Corporation Disconnect the blue tube running from the solenoid to the hot tank inlet see figure for location of this tube Thread the blue tubing through the hole in the shelf as shown above as s...

Page 16: ...cooler to the mains supply Drain at least 5 litres of hot water from the outlet before switching on the hot tank THIS APPLIANCE MUST BE EARTHED This appliance is not suitable for unsupervised use by y...

Reviews: