This  appliance  can  be  used  by  children  aged  from  8  years  and  above  and  persons  
with    reduced    physical,  sensory    or    mental    capabilities    or    lack    of    experience    and   
knowledge    if    they    have    been    given    supervision    or  instruction  concerning  use  of  the 
appliance in a safe way and understand the hazards involved. Children shall

 

not play with 

the appliance. Cleaning  and  user  maintenance  shall  not  be  made  by  children  without 
supervision.

The appliance shall be installed in accordance with national wiring regulations.

 If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or 
similarly qualified persons in order to avoid a hazard.

Before obtaining access to terminals, all supply circuits must be disconnected.

Do not operate your air conditioner in a wet room such as a bathroom or laundry room.

An  all-pole  disconnection  device  which  has  at  least  3mm  clearances

 

in  all  pole

s

 

,  and 

have a leakage current that may exceed 10mA

, the 

residual current device (RCD) having 

a  rated  residual  operating  current  not  exceeding  30mA

,  and 

disconnection  must  be 

incorporated in the fixed wiring in accordance with the wiring rules

.

1. PREFACE

2

Do  not  use  means  to  accelerate  the  defrosting  process  or  to  clean,  other  than  those 
recommended by the manufacturer

The appliance shall be stored in a room without continuously operating ignition sources (for 
example: open flames, an operating gas appliance or an operating electric heater.)

Do not pierce or burn

Appliance shall be installed, operated and stored in a room with a floor area larger than X 
m2  
Be aware that refrigerants may not contain an odour. 
The installation of pipe-work shall be kept to a minimum X m2 
Spaces where refrigerant pipes shall be compliance with national gas regulations. 
Servicing shall be performed only as recommended by the manufacturer. 
The appliance shall be stored in a well-ventilated area where the room size corresponds to 
the room area as specified for operation.
All working procedure that affets safety means shall only be carried by competent persons.

  

Transport of equipment containing flammable refrigerants 
Compliance with the transport regulations 
Marking of equipment using signs
Compliance with local regulations 
Disposal of equipment using flammable refrigerants
Compliance with national regulations 
Storage of equipment/appliances 
The storage of equipment should be in accordance with the manufacturer's instructions.  
Storage of packed (unsold) equipment 
Storage package protection should be constructed such that mechanical damage to the 
equipment inside the package will not cause a leak of the refrigerant charge. 
The maximum number of pieces of equipment permitted to be stored together will be 
determined by local regulations. 

1. PREFACE

In order to provide our customers with quality, reliability and  versatility, this product has 
been made to strict production standards. This manual  includes all the necessary 
information about  installation, debugging, discharging and maintenance. Please read this 
manual carefully before you open or maintain the unit. The manufacture of this product will 
not be held responsible if someone is injured or the unit is damaged,  as a result of 
improper installation, debugging, or unnecessary maintenance. It is vital that the 
instructions within this  manual are adhered to at all times. The unit must be installed by 
qualified personnel.

The unit can only be repaired by qualified installer centre , personnel or an authorised 
dealer.

Maintenance and operation must be carried out according to the recomended time and 
frequency, as stated in this manual.

Use genuine standard spare parts only.
Failure to comply with these recommendations will invalidate the  warranty.

Swimming Pool Heat Pump Unit heats the swimming pool water and keeps the temperature 
constant.   For split type unit, The indoor unit can be Discretely hidden or semi-hidden to 
suit a luxury house.

Our heat pump has  following characteristics:

1 Durable
      The heat exchanger is made of PVC & Titanium  tube which can withstand prolonged 
exposure to swimming pool water.
2 Installation flexibility
      The unit can be installed outdoors.
3 Quiet operation
      The unit comprises an efficient rotary/ scroll compressor and a low-noise fan motor, 
which guarantees  its quiet operation.
4  Advanced controlling
      The unit includes micro-computer controlling, allowing all operation parameters to be 
set. Operation status can be displayed on the LCD wire controller. Remote controller can be 
chosen  as future option.

1

WARNING

Do not use means to accelerate the defrosting process or to clean,
Other than those recimmended by the manufacturer.

The appliance shall be stored in a room without continuously 
operating  ignition  sources  (for example:open flames, an 
Operating gas appliance or an operating electric heater.)

Do not pierce or burn.

Be aware that refrigerants may not contain an odour,

Appliance shall be installed,operated and stored in a room with a floor area larger
 than 30 

.

Summary of Contents for I19

Page 1: ...SWIMMING POOL HEAT PUMP UNIT Installation Instruction Manual...

Page 2: ......

Page 3: ...ch 4 5 4 6 4 7 Silent 4 8 4 9 4 10 4 11 Main board 5 Maintenance and Inspection 6 Appendix Installation illustration Swimming Pool Heat Pumps Location Parameter list and breakdown table Cable specific...

Page 4: ...mming pool water and keeps the temperature constant For split type unit The indoor unit can be Discretely hidden or semi hidden to suit a luxury house Our heat pump has following characteristics 1 Dur...

Page 5: ...The appliance shall be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater Do not pierce or burn Applia...

Page 6: ...eparately from domestic waste must be taken to a recycling centre for electric and electronic devices or handed back to the dealer when purchasing an equivalent appliance 6 Directive 2002 95 EC RoHs T...

Page 7: ...oise Water Connection Water Flow Volume Water Pressure Drop max Unit Net Dimensions L W H Unit Ship Dimensions L W H Net Weight Shipping Weight Nominal Heating Capacity kW Btu h kW Btu h kW kW A A W R...

Page 8: ...antity Compressor Fan Quantity Fan Power Input Fan Rotate Speed Fan Direction Noise Water Connection Water Flow Volume Water Pressure Drop max Unit Net Dimensions L W H Unit Ship Dimensions L W H Net...

Page 9: ...2 2 The dimensions for Swimming Pool Heat Pump Unit Modles Oasis I9 Oasis I12 unit mm 2 SPECIFICATION 6 545 956 1000 398...

Page 10: ...2 2 The dimensions for Swimming Pool Heat Pump Unit Models Oasis I19 unit mm 2 SPECIFICATION 7 Water inlet 40 Water outlet 40 96 790 490 862 466 1115 1160 467...

Page 11: ...teps when using for the first time 1 Open valve and charge water 2 Make sure that the pump and the water in pipe have been filled with water 3 Close the valve and start the unit ATTN It is necessary t...

Page 12: ...us source of fresh air which reduces it efficiency and may prevent adequate heat delivery 3 2 Swimming Pool Heat Pumps Location Normally the pool heat pump is installed within 7 5 metres of the pool T...

Page 13: ...o the basepan and drain out through the barbed plastic condensation drain fitting on the side of the basepan This fitting is designed to accept 20mm clear vinyl tubing which can be pushed on by hand a...

Page 14: ...our pool pump is running when the pool temperature drops more than 0 2 below set temperature Time Delay The unit is equipped with a 3 minute built in solid state restart delay included to protect cont...

Page 15: ...ed to enter and exit the mute mode with one click 4 2 Key and icon function instruction Key symbols It is used to switch the unit mode temperature setting and parameter setting It is used to carry out...

Page 16: ...the unit It will display when compressor is started It will display when water pump is started It will display when fan is started When the timing mute function is started it keeps bright for a long...

Page 17: ...shut down the wire controller will display as follows Operations are the same as under ON OFF main interface 4 4 Mode switch Under the main interface Short press to switch the unit among heating cooli...

Page 18: ...When the unit is under the defrosting state the defrosting symbol is on with the display interface as follows Notes 1 After completing the defrosting the unit will be automatically switched to the hea...

Page 19: ...erating steps the changes will not be saved and return to the main interface Under the clock setting interface Long press for 2 s to enter into the system times setting interface Short press Press or...

Page 20: ...interface Notes 1 Under the Timer ON OFF setting interface if there is no operation for 20 s the system will automatically memorize user s settings and return to the main interface 2 Under the Timer O...

Page 21: ...p long press of for 2 s Short press or Short press for entering the hour digit setting of timing on silent Short press or Short press for confirming the timing on silent and turn to the setting of tim...

Page 22: ...nd the screen will be lighten after other operations conducted 2 Under the OFF interface locking operation is available and the operation method is the same as locking screen under the ON interface 2...

Page 23: ...sor Check the pressure switch and cold circuit Check or change the temp Sensor Check the pressure switch and cold circuit check and replace this temp sensor Check whether fan motor is broken or locked...

Page 24: ...nt Check the input voltage measurement Check the input voltage measurement Check and adjust the current measurement Check the communication connection Check the PFC switch tube short circuit or not Ch...

Page 25: ...n Instruction 10 2 Parameter list Meaning 28 28 27 Remarks Adjustable Adjustable Adjustable Default Refrigeration target temperature set point Heating the target temperature set point Automatic target...

Page 26: ...23 Controller interface diagram and definition 4 11 Main board Oasis I9 I12 4 Use and Operation Instruction 1 2 3 1 2 1 2 A B 1 2 1 2 4 5 6 3 1 2 4 5 6 3 1 2 1 2 1 2 4 5 6 3 7 8 9 1 2 ACN1 ACL1...

Page 27: ...1 2 3 1 2 1 2 A B 1 2 1 2 4 5 6 3 1 2 4 5 6 3 1 2 1 2 1 2 4 5 6 3 7 8 9 Controller interface diagram and definition 4 11 Main board Oasis I19 24 4 Use and Operation Instruction 1 2...

Page 28: ...put Water output temperature input System fan coil temperature input Ambient temperature input System Exhaust temperature input Earth wire Earth wire System suction temperature input Water input tempe...

Page 29: ...Work procedure Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or vapour being present while the work is being performed Work procedure Work shall b...

Page 30: ...times the manufacturer s maintenance and service guidelines shall be followed If in doubt consult the manufacturer s technical department for assistance The following checks shall be applied to instal...

Page 31: ...sphere from a leak Cabling Check that cabling will not be subject to wear corrosion excessive pressure vibration sharp edges or any other adverse environmental effects The check shall also take into a...

Page 32: ...e that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrigerant recovery cylinders are employed Ensure that the correct number of cylin...

Page 33: ...le before the task is commenced a Become familiar with the equipment and its operation b Isolate system electrically c Before attempting the procedure ensure that Mechanical handling equipment is avai...

Page 34: ...line MCB Creepage protector Signal line 2 n 0 5mm Nameplate maximum current Earth line No more than 10A 20A 32A 40A 40A 63A 80A 100A 125A 160A 225A 250A 280A 2 1 5mm 2 2 5mm 2 4mm 2 6mm 2 10mm 2 16mm...

Page 35: ...emperature R410A Pressure MPa Temperature R32 Temperature R410A Temperature R32 0 0 3 0 5 0 8 1 1 3 1 5 1 8 2 2 3 2 5 2 8 3 3 3 3 5 3 8 4 4 5 5 5 5 51 3 20 9 4 11 19 24 31 35 39 52 5 20 9 3 5 10 18 23...

Page 36: ...33 6 APPENDIX 6 3 Explosive view of the unit Moddel Oasis I9 Complete machine structure explosion diagram Electrical control structure explosion diagram...

Page 37: ...e switch Needle valve Pressure switch Water flow switch There way valve Electronic expansion valve There way valve Filter Four way valve Junction box body Right side of the plate Titanium tube heat ex...

Page 38: ...35 6 APPENDIX 6 3 Explosive view of the unit Moddel Oasis I12 Complete machine structure explosion diagram Electrical control structure explosion diagram...

Page 39: ...re switch Needle valve Pressure switch Water flow switch There way valve Electronic expansion valve There way valve Filter Four way valve Junction box body Right side of the plate Titanium tube heat e...

Page 40: ...6 APPENDIX 6 3 Explosive view of the unit 37 Moddel Oasis I19 Complete machine structure explosion diagram Electrical control structure explosion diagram...

Page 41: ...Needle valve Pressure switch Water flow switch There way valve Electronic expansion valve There way valve Filter Four way valve Junction box body Right side of the plate Titanium tube heat exchanger...

Page 42: ...Note...

Page 43: ......

Page 44: ...Code 20190508 0001...