4.Use and Operation Instruction
14
13
2.2.Icon function instruction
4.Use and Operation Instruction
Icon symbol Designation
Function
Cooling
symbol
Heating
symbol
Automatic
symbol
Defrosting
symbol
Compressor
symbol
Water pump
symbol
Fan symbol
Mute symbol
Timing symbol
Water outlet
symbol
Water inlet
symbol
Locking key
symbol
Fault symbol
Wireless signal
symbol
Degrees Celsius
symbo l
Degrees Fahrenheit
symbol
Setting symbol
Second symbol
Minute symbol
Hour symbol
Pressure
symbol
Flow symbol
It will display during cooling (there is no limit to startup &
shutdown, and it is optional when the unit is cooling-only
unit or heating-and-cooling unit).
It will display during heating (there is no limit to startup &
shutdown, and it is optional when the unit is heating-only
unit or heating-and-cooling unit).
It will display under the automatic mode (there is no limit to
startup & shutdown, and it is optional when the unit is heating-
and-cooling unit).
It will display in the defrosting process of the unit.
It will display when compressor is started.
It will display when water pump is started.
It will display when fan is started.
When the timing mute function is started, it keeps bright for a
long time. When it is in mute state, it will flash. Or else, it is off.
It will display after the user sets the timing, and multiple timing
intervals can be set .
When the axillary display area displays the water outlet
temperature, the light is on.
When the main display area displays the water inlet temperature,
the light is on.
When the keyboard is locked, it is on.
In case of unit fault, it is on.
When the unit is connected to WIFI module, it will display
according to the strength of WIFI signal.
When main display area or auxiliary display area displays
degrees Celsius, it is on.
When main display area or auxiliary display area displays
degrees Fahrenheit, it is on.
When the parameter is adjustable, it is on
When main display area displays second digit, it is on.
When main display area displays minute digit, it is on.
When main display area displays hour digit, it is on.
When main display area displays pressure, it is on.
When main display area displays flow, it is on.
4.
3. Startup & shutdown
Keep long press of " "for 0.5 s
to enter ON/OFF interface
When there is no operation
within 15 minutes, it will
display with full screen off
When the unit is started under the control of wire controller, if using the emergency switch to
shut down, the wire controller will display as follows:
Operations are the same as under ON/OFF main interface.
4.4. Mode switch
Under the main interface, Short press" "to switch the unit among heating
, cooling
and automatic mode " ".
" "
" "
When there is no operation
within 1 minute, it will display
with half screen off
Notes:
Startup & shutdown operation can only be conducted in the main interface.
When it displays with half screen off or full screen off, click any key for returning to ON/OFF
main interface.