SERVICE INSTRUCTIONS 

B.  CLEANING THE SPRAYHEAD

 

 

Over time mineral build up may develop around the 
(6) spray holes on the spray head which may lead to 
pot volume variances.  Periodic inspection and 
cleaning of the spray head is recommended. 
 
1.  Turn spray head counter clockwise a quarter 

turn until it stops (see figure 6). 

2.  The spray head and the brew basket rail will 

drop straight down to remove. 

3.  Remove gasket from spray head when cleaning.
4.  Reassemble spray head and brew basket rail 

using reverse procedure.  Make sure spray 
head detents (clicks) into place when 
reassembling. 

Figure 6 

Spray head removal Illustration 

Brew Basket Rails

Spray Head Gasket 

Spray Head

Figure 5 

Thermostat Adjustment Illustration

 

A.  ADJUSTING HOT TANK THERMOSTAT

 

 

 

 
 

Whenever thermostat adjustment becomes 
necessary, complete the following procedure: 

1.  Disconnect power cord from electrical 

outlet. 

2.  Remove (2) screws and rear panel (see 

figure 5). 

3.  Use a bladed screwdriver to adjust the 

thermostat knob (see figure 5).  Turn 
clockwise for hotter water temperature 
and counter clockwise for cooler water 
temperature. 

4.  Replace rear panel and (2) screws. 
5.  Plug power cord into electrical outlet and 

follow steps 1-3 in ENERGIZE 
BREWER/HOT TANK HEAT UP 

Thermostat 

Adjustment Knob

Rear Panel 

On/Off main 
power switch
 
IEC Cord 
Receptacle 

3/8” Quick Tube 

Connect

Rear Switch Plate 
Screws (2) 

C.  REMOVING HOT TANK ASSEMBLY FROM CABINET ASSEMBLY 

1.  Turn the main water supply to brewer OFF. 
2.  Disconnect the power cord from both the electrical outlet 

and the IEC plug located at the rear of the brewer (see 
figure 5). 

3.  Disconnect 3/8 inch supply tube from quick tube connect 

(see Figure 5). 

 

NOTE:

 

If hot tank is full, water will dribble from the 
external tube fitting.  It is recommended that 
the fitting be plugged with the provided 3/8 
inch plug. 

 

4.  Remove cover from cabinet assembly. 
5.  Remove (2) screws and rear panel (see figure 5). 
6.  Pull drain tube out rear access opening. 
7.  Remove plug from end of drain tube. 
 

CAUTION:

  HOT WATER WILL IMIDIATLY FLOW 

FROM DRAIN TUBE. 

 

8.  Remove ribbon cable for circuit board. 
9.  Let tank completely drain of water. 
10.  When finished draining tank, replace the drain tube plug.
11.  Remove silicone tube from hot water faucet fitting. 
12.  Remove molded silicone tube from spray head top. 
13.  Remove (2) screws from rear switch plate (see figure 5). 
14.  Remove hot tank assembly from cabinet by lifting from 

the upper plastic reservoir (see figure 7). 

 

Hot Water 
Faucet Outlet 
Opening 

Figure 5 

Thermostat Adjustment Illustration 

Figure 7 

Hot Tank / Cabinet Assembly 

Cabinet 

Assembly

Hot Tank 

Assembly

Cover

Summary of Contents for FreshStart FSTB-A60

Page 1: ...Box 3150 Columbus OH 43213 0150 1 800 64 OASIS 1 800 646 2747 www OasisWaterCoolers com FSTB A60 FSTB A60C Length 20 1 2 Height 16 7 8 Width 9 7 8 1430 Watts 12 Amps 120 Volts Model includes carafe FSTB A80 Length 20 1 2 Height 21 1 2 Width 10 1 4 1430 Watts 12 Amps 120 Volts Manual PN 30099 256 ...

Page 2: ...beyond 90PSI a pressure regulator should be installed Flush water line prior to installing brewer Brewer should be connected to a COLD WATER LINE 1 Place brewer on a level surface 2 Insert water supply tube into external fitting see figure 1 Brewer is equipped with an external fitting located at rear capable of accepting a 3 8 tube NOTE Brewers are shipped with a plug in the external fitting Plug ...

Page 3: ...er is shut off to the brewer by pushing the ON OFF MAIN POWER switch to the OFF position 2 Press and hold down the BREW FULL POT button on the front control panel 3 While holding down the BREW FULL POT button push the ON OFF MAIN POWER switch at the rear of the unit to the ON position 4 Once the ON OFF MAIN POWER switch has been pushed to the ON position the BREW FULL POT button can be released Th...

Page 4: ...will stop flowing A BREWING COFFEE 1 Remove brew basket from brewer 2 Place one 1 standard commercial filter 9 5 inch diameter into brew basket 3 Put required amount of coffee grounds into filter and shake brew basket to level off coffee grounds 4 Return brew basket to brewer NOTE Brew basket is designed to click into place when properly installed This action secures the brew basket to the cabinet...

Page 5: ...n ENERGIZE BREWER HOT TANK HEAT UP Thermostat Adjustment Knob Rear Panel On Off main power switch IEC Cord Receptacle 3 8 Quick Tube Connect Rear Switch Plate Screws 2 C REMOVING HOT TANK ASSEMBLY FROM CABINET ASSEMBLY 1 Turn the main water supply to brewer OFF 2 Disconnect the power cord from both the electrical outlet and the IEC plug located at the rear of the brewer see figure 5 3 Disconnect 3...

Page 6: ...the bracket assembly Once the screws have been loosened the solenoid valve can be removed from the bracket slots see figure 10 8 If replacement is required assemble a new or refurbished dump solenoid valve in the reverse order G THERMOSTAT REPLACEMENT Primary Thermostat see figure11 1 Disconnect the power cord from both the electrical outlet and the IEC plug located at the rear of the brewer see f...

Page 7: ...1 Drain hot tank see Section C steps 1 8 2 Remove silicone tube from hot faucet 3 Remove 4 front panel assembly screws from inside cabinet 4 Remove 2 faucet bracket screws from front panel assembly 5 Loosen hot faucet nut and remove faucet from bracket 6 Replace hot faucet using the reverse order NOTE If dripping from hot faucet occurs the bonnet see Figure13 may be too loose To tighten turn bonne...

Page 8: ...ervice Instructions Section G Replace heating element Carafe Overflows Verify carafe is empty before brewing fresh pot Verify supply line pressure if needed add a pressure regulator Check that float arms are moving up and down freely and are not binding see Service Instructions Section D Check for mineral buildup clogs or kinks to water lines and fittings Remove and dry air filter see Service Inst...

Reviews: