Oasis FreshStart FSTB-A60 Installation & Operation Manual Download Page 4

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

OPERATION INSTRUCTIONS 

B.  CANCELLING A BREW CYCLE 

To cancel a brew cycle that is in process, press the 

ON/OFF BREW CANCEL

 button located on the front control 

panel.  When canceling a brew cycle, water is shut off to the spray head, but the brew basket will continue to drain 
until depleted.

 

C.  CUP DRAW FROM SAFTEY FAUCET

 

 

CAUTION:  

WATER FROM SAFETY FAUCET IS HOT

 

 

 
 

 

 

Figure 4 

Safety Faucet Illustration 

To draw a cup of hot water from the safety hot faucet (red button 
located on the front panel of the brewer): 

1.  Place an empty cup directly under the non-textured bump 

out located directly under the CAUTION HOT WATER label 
(see figure 4). 

2.  Push the red button down and forward to start the flow of 

hot water. 

3.  When finished, release button.  Button will return to original 

position and hot water will stop flowing. 

A. BREWING 

COFFEE

 

 1.  Remove brew basket from brewer. 

2.  Place one (1) standard commercial filter (9.5 inch 

diameter) into brew basket. 

3.  Put required amount of coffee grounds into filter and 

shake brew basket to level off coffee grounds. 

4.  Return brew basket to brewer. 
 

NOTE:

 

Brew basket is designed to click into 
place when properly installed.  This action 
secures the brew basket to the cabinet. 

 

5. Place 

appropriate 

EMPTY

 thermal carafe into position 

below the brew basket. 

6. Press 

the 

BREW (FULL POT) 

button for full pot volume 

or the 

BREW (HALF POT)

 button for half pot volume. 

 

NOTE:

 

The corresponding light above the chosen 

BREW

 button will blink for the duration of 

the brew cycle.  When light has stopped 
blinking, the brew cycle is complete and it 
is safe to remove the carafe. 

 

7.  After brewing is complete, remove brew basket and 

discard used coffee grounds and filter.

 

8.  Rinse brew basket and return to brewer.

 

Brew Basket

Filter/Coffee 

Placement

Figure 3 

Brew Basket Illustration

Summary of Contents for FreshStart FSTB-A60

Page 1: ...Box 3150 Columbus OH 43213 0150 1 800 64 OASIS 1 800 646 2747 www OasisWaterCoolers com FSTB A60 FSTB A60C Length 20 1 2 Height 16 7 8 Width 9 7 8 1430 Watts 12 Amps 120 Volts Model includes carafe FSTB A80 Length 20 1 2 Height 21 1 2 Width 10 1 4 1430 Watts 12 Amps 120 Volts Manual PN 30099 256 ...

Page 2: ...beyond 90PSI a pressure regulator should be installed Flush water line prior to installing brewer Brewer should be connected to a COLD WATER LINE 1 Place brewer on a level surface 2 Insert water supply tube into external fitting see figure 1 Brewer is equipped with an external fitting located at rear capable of accepting a 3 8 tube NOTE Brewers are shipped with a plug in the external fitting Plug ...

Page 3: ...er is shut off to the brewer by pushing the ON OFF MAIN POWER switch to the OFF position 2 Press and hold down the BREW FULL POT button on the front control panel 3 While holding down the BREW FULL POT button push the ON OFF MAIN POWER switch at the rear of the unit to the ON position 4 Once the ON OFF MAIN POWER switch has been pushed to the ON position the BREW FULL POT button can be released Th...

Page 4: ...will stop flowing A BREWING COFFEE 1 Remove brew basket from brewer 2 Place one 1 standard commercial filter 9 5 inch diameter into brew basket 3 Put required amount of coffee grounds into filter and shake brew basket to level off coffee grounds 4 Return brew basket to brewer NOTE Brew basket is designed to click into place when properly installed This action secures the brew basket to the cabinet...

Page 5: ...n ENERGIZE BREWER HOT TANK HEAT UP Thermostat Adjustment Knob Rear Panel On Off main power switch IEC Cord Receptacle 3 8 Quick Tube Connect Rear Switch Plate Screws 2 C REMOVING HOT TANK ASSEMBLY FROM CABINET ASSEMBLY 1 Turn the main water supply to brewer OFF 2 Disconnect the power cord from both the electrical outlet and the IEC plug located at the rear of the brewer see figure 5 3 Disconnect 3...

Page 6: ...the bracket assembly Once the screws have been loosened the solenoid valve can be removed from the bracket slots see figure 10 8 If replacement is required assemble a new or refurbished dump solenoid valve in the reverse order G THERMOSTAT REPLACEMENT Primary Thermostat see figure11 1 Disconnect the power cord from both the electrical outlet and the IEC plug located at the rear of the brewer see f...

Page 7: ...1 Drain hot tank see Section C steps 1 8 2 Remove silicone tube from hot faucet 3 Remove 4 front panel assembly screws from inside cabinet 4 Remove 2 faucet bracket screws from front panel assembly 5 Loosen hot faucet nut and remove faucet from bracket 6 Replace hot faucet using the reverse order NOTE If dripping from hot faucet occurs the bonnet see Figure13 may be too loose To tighten turn bonne...

Page 8: ...ervice Instructions Section G Replace heating element Carafe Overflows Verify carafe is empty before brewing fresh pot Verify supply line pressure if needed add a pressure regulator Check that float arms are moving up and down freely and are not binding see Service Instructions Section D Check for mineral buildup clogs or kinks to water lines and fittings Remove and dry air filter see Service Inst...