5
OVERVIEW / TYPE / COMPLIANCE / WARNINGS / PRECAUTIONS / WIRING / PLUGS
-
PAGE 2 of 2
PRECAUTIONS
•
Following are important precautions to prevent
damage to unit or merchandise.
•
Please read carefully!
•
See previous page for specifics on
OVERVIEW,
TYPE, COMPLIANCE
and
WARNINGS
.
WIRING DIAGRAM
•
Each case has its own wiring diagram folded and in its
own packet.
•
Placement on case varies (near ballast box, field
wiring box, raceway cover, or other related location).
REFRIGERANT DISCLOSURE STATEMENT
•
This equipment is prohibited from use in California
with any refrigerants on the
“
List of Prohibited
Substances
”
for that specific end
-
use, in accordance
with California Code of Regulations, title 17, section
95374.
•
This disclosure statement has been reviewed and
approved by Structural Concepts and Structural
Concepts attests, under penalty of perjury, that these
statements are true and accurate.
CAUTION! GFCI BREAKER USE REQUIREMENT
If N.E.C. (National Electric Code) or your local code
requires GFCI (Ground Fault Circuit Interrupter) protection,
you MUST use a GFCI breaker in lieu of a GFCI receptacle.
CAUTION! POWER CORD AND PLUG MAINTENANCE
Risk of electric shock. If cord or plug becomes damaged,
replace only with cord and plug of same type.
CAUTION! DO NOT RELY ON THERMOMETERS OR
THERMOSTATS FOR PRODUCT (FOOD) TEMPERATURES.
•
Thermometers & thermostats reflect air temperatures ONLY.
•
For ACTUAL product (food) temperatures, use a calibrated food
probe thermometers ONLY.
•
For accurate readings, DO NOT use infrared food thermometers.
CAUTION! LAMP REPLACEMENT GUIDELINES
If LED lamps are used, they must be size, shape and overall design.
Any replacements must meet factory specifications.
CAUTION! ADVERSE CONDITIONS / SPACING ISSUES
•
Performance issues caused by adverse conditions are NOT warranted.
•
To prevent damage to end panels due to condensation, apply industrial grade
silicone sealant and tightly join to opposite end panels. When not adjoining
cases, keep end panels at least
6”
away from walls/structures. Rear panels
must also be kept at least
6”
from walls and structures.
•
Case must not be exposed to direct sunlight or any heat source.
•
To maintain proper case temperature, keep case at least 15
-
feet from exterior
doors, overhead HVAC vents or any air curtain disruption.
•
Self
-
contained case clearance:
6”
min. air intake /
6”
min. air discharge.
CAUTION