![Oasis CO33R User Manual Download Page 18](http://html1.mh-extra.com/html/oasis/co33r/co33r_user-manual_4499334018.webp)
18
START
-
UP AND OPERATION, CONTINUED: LOAD LIMITS
18
PRODUCT PLACEMENT / HONEYCOMB AIRFLOW CONSIDERATION / LOAD LINES
1. Product Placement
•
Product can be placed on decking or steps
(risers) within self
-
service display area.
•
A wide range of product may be displayed.
2. Honeycomb Airflow Consideration
•
Airflow from honeycomb air diffuser is
designed to flow over (and around)
product to return air grille at case front.
•
Caution! You must keep the honeycomb
air diffuser unblocked by product for
airflow to reach return air grille.
•
Caution! You must ALSO keep product
OFF return air grill at case front.
•
See illustration below.
3. Load Lines
•
Load lines represent the maximum
height that product can be place and/
or stacked in case.
•
Keep product at or under load lines to
assure that refrigerated airflow is
properly cycled from honeycomb air
diffuser through the return air grille.
•
Proper product placement will
maintain acceptable
product temperature.
•
See illustration below.
Return Air Grille Must Not
Be Blocked By Product!
Sample Product
Note: Perspective View of Model
CO5324R Is Shown At Right. It May
Not Exactly Reflect Every Feature or
Option of Your Particular Case.
4.00”
3.66”
UPPER LOAD
LINE ORIGIN:
LOWER
EDGE OF
HONEYCOMB
DISCHARGE
LOWER LOAD LINE
ORIGIN: FRONT ACRYLIC
AND DECK SURFACE
DIMENSIONAL
INTERSECTION.