OWNER’S MANUAL

  |  OASIS SERIES 3000 WASTEWATER TREATMENT SYSTEM  |  19

LIMITED 

WARRANTY

Oasis Clearwater Systems warrants each Oasis 

Series 3000 Aerobic Wastewater Treatment 

System to be free from defects in material 

and workmanship for a period of two (2) 

years from the date of sale to the ultimate 

consumer when properly registered with 

Oasis Clearwater Systems. Oasis Clearwater 

System’s sole obligation under this warranty 

is as follows: Oasis Clearwater Systems 

shall fulfil this warranty by repairing or 

exchanging any component part, ex factory, 

that shows evidence of defects, provided said 

component part has been paid for, warrantee 

has notified Oasis Clearwater Systems of the 

defect complained of and the component is 

returned through an authorised Distributor, 

transportation prepaid. There is no informal 

dispute settlement available under this  

LIMITED WARRANTY. 
No warranty is made as to the field performance 

of any system. This LIMITED WARRANTY applies 

only to the parts manufactured by Oasis 

Clearwater Systems and does not include any 

portion of the plumbing, drainage or installation 

of the systems, and does not include any 

travel or labour. Accessories supplied by Oasis 

Clearwater Systems, but manufactured by 

others, are warranted only to the extent of and 

by the terms and conditions of the original 

manufacturer’s warranty. In no event shall 

Oasis Clearwater Systems be responsible for 

delay or damages or any kind of character 

resulting from, or caused directly or indirectly 

by, defective components or materials 

manufactured by others. 
Recommendations for special applications 

will be based on the best available expertise 

of Oasis Clearwater Systems and published 

industry information. Such recommendations 

do not constitute a warranty of satisfactory 

performance. 
This LIMITED WARRANTY extends to the 

ultimate consumer of the product.  

As herein, “ultimate consumer” is defined as 

the purchaser who first has the plant installed, 

or in the case of a system designed for non-

permanent installation, the purchaser who 

first uses the system. It is the purchaser’s or 

any sub-vendee’s obligation to make known to 

any other consumer, the terms and conditions 

of this warranty. This warranty is a LIMITED 

WARRANTY and no claim of any nature shall 

be made against Oasis Clearwater Systems 

unless and until the ultimate consumer, or his 

legal representative, notifies Oasis Clearwater 

Systems in writing of the defect complained 

of and delivers the product and/or defective 

part(s), freight prepaid, to Oasis Clearwater 

Systems or an authorised service agent. 
Oasis Clearwater Systems reserves the right 

to revise, change or modify the construction 

and design of the Oasis Series 3000 Aerobic 

Treatment System, or any component part or 

parts thereof, without incurring any obligation 

to make such changes or modifications in 

equipment previously sold. Oasis Clearwater 

Systems also reserves the right, in making 

replacements of component parts under this 

warranty, to furnish a component part which, in 

its judgement is equivalent to the part replaced. 

SERVICING  

Your system must be serviced by Oasis 

Clearwater Environmental Systems or an 

authorised agent. If the system is not serviced 

at 6 monthly intervals all warranties will be 

voided. 

WATER INGRESS  

All wastewater treatment systems are designed 

to treat 

controlled domestic (human) 

wastewater inflows ONLY.

 If the flows exceed 

design parameters due to wet weather 

(stormwater ingress, etc) or uncontrolled 

inflows (failed cisterns, automatic urinals, etc) 

all target design parameters and warranty will 

be voided.

Summary of Contents for 3000 Series

Page 1: ...OWNER S MANUAL OASIS SERIES 3000 WASTEWATER TREATMENT SYSTEM...

Page 2: ...future reference If you have questions regarding the safety and operation of your Series 3000 Sewerage Treatment System contact your local authorised Service Technician Do not attempt to service compo...

Page 3: ...ENT SYSTEM 1 CONTENTS An overview 2 How the system works 3 Putting stuff into the system 4 System maintenance and monitoring 8 Troubleshooting 10 Service procedure 14 Instructions for controller 15 Al...

Page 4: ...w how the Oasis Series 3000 Wastewater Treatment System works Process flow may differ from one location to another 1st Chamber Primary settling Pump Chamber Pumps to irrigation field 5th Chamber Clari...

Page 5: ...g to a secondary treatment chamber Liquid flows into the aeration chambers where with the use of our exclusive fine air diffuser assemblies thousands of tiny air bubbles provide oxygen for aerobic dig...

Page 6: ...ances that reduce the efficiency or stop the treatment process can be grouped into two groups prohibited matter and limited use substances While the Wastewater Treatment System will process most domes...

Page 7: ...ns condoms baby wipes and disposable napkins Toxic substances such as pesticides herbicides strong disinfectants and strong caustic drain cleaners Large amounts of paper products such as paper towels...

Page 8: ...to the manufacturer s directions don t use these substances very often and do not introduce concentrated doses into the system Laundry bleach Detergents with bleach Household cleaners containing sodi...

Page 9: ...e treated by the system but will remain in solid form and fall to the bottom of the septic tank Therefore you should consider not using a waste grinder system Do not dispose of these food items throug...

Page 10: ...ice policy which includes two inspection service calls per annum to ensure proper operation of the system During these service calls the authorised service person will check the blower for proper oper...

Page 11: ...lower is not operating follow the procedures given under alarm wiring Flooding Flood water may cover the septic unit the blower housing or both affecting the electrics if the system is installed in a...

Page 12: ...tarvation of the biomass The blower inlet filter should be checked every 6 months and replaced as needed 10 Visual evaluation Wastewater backup is characterised by wastewater flowing back into the hou...

Page 13: ...lure high flows etc and correct The blower has failed Determine if blower failure was caused by an obstructed intake or discharge line Investigate overheating i e internal thermal overload protection...

Page 14: ...d lateral field piping visually or with drain cleaning equipment for an obstruction and correct The flow rate to the system is too high Check the maximum flow rate to the system to see that it is with...

Page 15: ...The blower and air piping are not operating correctly Check the blower vents and air piping for proper operation The system is overloaded Check the maximum flow rate to the unit to see that it is wit...

Page 16: ...rking 7 Double check the audio visual alarm and make sure the Mute button is in the ON position 8 Irrigation field inspection and dripline line flushing Servicing procedure 1 Ensure correct NAME ADDRE...

Page 17: ...ion of 24 hours as a reminder that the plant is not operating correctly The visual alarms cannot be turned off until all faults are rectified Introduction The Oasis Clearwater Control Panel has a numb...

Page 18: ...p of turret and secure hose onto air pipe High Water Fault High Level Fault Call 0800 484 849 The fluid level in the irrigation tank is high Check irrigation filter is clean Check that the pump is run...

Page 19: ...ALARM LED TANK ALARM TEXT REMOTE PANEL CAUSE SOLUTION N A Oasis Clearwater System OK Oasis Clearwater Holiday Mode alternates The irrigation pump has not run in 48 hours This is not a fault condition...

Page 20: ...try to reset the system with the following sequence a Turn the system OFF using the control panel ON OFF switch on the side of the panel This will reset the programme b Turn the system ON using the ON...

Page 21: ...ed industry information Such recommendations do not constitute a warranty of satisfactory performance This LIMITED WARRANTY extends to the ultimate consumer of the product As herein ultimate consumer...

Page 22: ...Head Office A PO Box 16276 Hornby Christchurch 8441 P 0800 48 48 49 F 03 344 0267 E office oasisclearwater co nz W oasisclearwater co nz oasisclearwater co nz...

Reviews: