12
The water alarm
is on.
An alarm condition
has occurred. See
troubleshooting items
under flashing alarm
indicator.
Push mute button to silence
alarm.
Pump failure.
Check levels in all chambers.
Check pump is functioning.
Check that the pump float is
not jammed and is free of walls
and any other obstructions
which may affect functioning.
Filter blocked.
Dismantle pump filter and
clean.
There is an obstruction in
the discharge line from the
system.
Check the effluent piping and
lateral field piping visually or
with drain cleaning equipment
for an obstruction and correct.
The flow rate to the system
is too high.
Check the maximum flow rate
to the system to see that it is
within normal limits.
Wastewater is
backing up into
the home sewer
piping.
There is an obstruction in
the home sewer piping.
Check the piping lead to the
system visually or with drain
cleaning equipment for an
obstruction and correct.
The tank requires cleaning
and / or a pumpout is
required.
Check the sludge depth in both
chambers of the tank to see
if it is below required levels.
If the depth is too great, have
the tank pumped out and, if
necessary, cleaned.
CONT...
TROUBLESHOOTING