ALARM CODES

ALARM  

LED - TANK

ALARM TEXT - 

REMOTE PANEL

CAUSE

SOLUTION

Air Fault

Air Fault Call  

0800 484 849

The blower’s  

diaphragms have failed

The blower’s diaphragms 

need to be replaced

The air hose has come 

off the pressure switch  

at based of controller

Remove the top of 

the turret attachment 

and secure hose onto 

pressure switch

The air hose has come 

off the air piping in side 

the turret

Remove top of turret 

and secure hose onto 

air pipe

High Water  

Fault

High Level Fault Call 

0800 484 849

The fluid level in the 

irrigation tank is high

Check irrigation  

filter is clean

Check that the pump  

is running and  

pumping freely

The float is caught in  

the high level position

Check float position  

and move to stop it 

being caught

Power Fault

Overload Fault Call 

0800 484 849

N/A

N/A

Check Filter

Pump Max Run  

Check Filter

The irrigation pump 

has been running in 

excess of 30 minutes 

continuously

Check and clean  

the irrigation filter

Check the irrigation 

field has no 

obstructions to letting 

the fluid flow

Summary of Contents for 3000 Series

Page 1: ...OWNER S MANUAL OASIS SERIES 3000 WASTEWATER TREATMENT SYSTEM...

Page 2: ...future reference If you have questions regarding the safety and operation of your Series 3000 Sewerage Treatment System contact your local authorised Service Technician Do not attempt to service compo...

Page 3: ...ENT SYSTEM 1 CONTENTS An overview 2 How the system works 3 Putting stuff into the system 4 System maintenance and monitoring 8 Troubleshooting 10 Service procedure 14 Instructions for controller 15 Al...

Page 4: ...w how the Oasis Series 3000 Wastewater Treatment System works Process flow may differ from one location to another 1st Chamber Primary settling Pump Chamber Pumps to irrigation field 5th Chamber Clari...

Page 5: ...g to a secondary treatment chamber Liquid flows into the aeration chambers where with the use of our exclusive fine air diffuser assemblies thousands of tiny air bubbles provide oxygen for aerobic dig...

Page 6: ...ances that reduce the efficiency or stop the treatment process can be grouped into two groups prohibited matter and limited use substances While the Wastewater Treatment System will process most domes...

Page 7: ...ns condoms baby wipes and disposable napkins Toxic substances such as pesticides herbicides strong disinfectants and strong caustic drain cleaners Large amounts of paper products such as paper towels...

Page 8: ...to the manufacturer s directions don t use these substances very often and do not introduce concentrated doses into the system Laundry bleach Detergents with bleach Household cleaners containing sodi...

Page 9: ...e treated by the system but will remain in solid form and fall to the bottom of the septic tank Therefore you should consider not using a waste grinder system Do not dispose of these food items throug...

Page 10: ...ice policy which includes two inspection service calls per annum to ensure proper operation of the system During these service calls the authorised service person will check the blower for proper oper...

Page 11: ...lower is not operating follow the procedures given under alarm wiring Flooding Flood water may cover the septic unit the blower housing or both affecting the electrics if the system is installed in a...

Page 12: ...tarvation of the biomass The blower inlet filter should be checked every 6 months and replaced as needed 10 Visual evaluation Wastewater backup is characterised by wastewater flowing back into the hou...

Page 13: ...lure high flows etc and correct The blower has failed Determine if blower failure was caused by an obstructed intake or discharge line Investigate overheating i e internal thermal overload protection...

Page 14: ...d lateral field piping visually or with drain cleaning equipment for an obstruction and correct The flow rate to the system is too high Check the maximum flow rate to the system to see that it is with...

Page 15: ...The blower and air piping are not operating correctly Check the blower vents and air piping for proper operation The system is overloaded Check the maximum flow rate to the unit to see that it is wit...

Page 16: ...rking 7 Double check the audio visual alarm and make sure the Mute button is in the ON position 8 Irrigation field inspection and dripline line flushing Servicing procedure 1 Ensure correct NAME ADDRE...

Page 17: ...ion of 24 hours as a reminder that the plant is not operating correctly The visual alarms cannot be turned off until all faults are rectified Introduction The Oasis Clearwater Control Panel has a numb...

Page 18: ...p of turret and secure hose onto air pipe High Water Fault High Level Fault Call 0800 484 849 The fluid level in the irrigation tank is high Check irrigation filter is clean Check that the pump is run...

Page 19: ...ALARM LED TANK ALARM TEXT REMOTE PANEL CAUSE SOLUTION N A Oasis Clearwater System OK Oasis Clearwater Holiday Mode alternates The irrigation pump has not run in 48 hours This is not a fault condition...

Page 20: ...try to reset the system with the following sequence a Turn the system OFF using the control panel ON OFF switch on the side of the panel This will reset the programme b Turn the system ON using the ON...

Page 21: ...ed industry information Such recommendations do not constitute a warranty of satisfactory performance This LIMITED WARRANTY extends to the ultimate consumer of the product As herein ultimate consumer...

Page 22: ...Head Office A PO Box 16276 Hornby Christchurch 8441 P 0800 48 48 49 F 03 344 0267 E office oasisclearwater co nz W oasisclearwater co nz oasisclearwater co nz...

Reviews: