CX Logix Operation MANUAL
– Updated July 2022
Page 10 of 15
pH2 Demand or Prime
– Add acid manually or prime clear flexible PVC tubes
The ‘pH2 DEMAND or PRIME’ quantity can be manually adjusted from 0 - 5000 ml. The default reading
is always 100 ml. This function is useful for:
-
Priming tubes after an acid drum change.
-
Adding the required acid from your acid demand test.
IMPORTANT:
Enter the exact amount from your test result in ml (e.g., 500ml) and the system
automatically adds 4 times that amount, thereby allowing for the 1:3 ACID: WATER mix ratio in
the acid drum.
T
o enter a required amount of acid in mL, enter the ‘pH2 Demand or
Prime’ menu from the ‘pH Control Mode’ menu explained in 10.1, using
the [+], [-] & [OK] button
The LCD
will now show ‘Acid Demand: 100 ml’.
Press [+] or [-] to adjust the quantity of acid required in millilitres (ml).
Pressing [OK] saves the required quantity, the peristaltic pump starts
turning and the ml reading starts counting down.
You can adjust the quantity in this menu if you wish or you can press
[<] and return to the chlorinator default display screen.
If the lines are primed, you can stop the peristaltic pump by entering a
reading of ‘0 ml’.
Turning OFF the CX Logix
Enter the pH Control Mode menu on the Oasis CX Premium Salt & Mineral Chlorinator.
On the power pack press OK to access the Main Menu system and use
the +/-
buttons to scroll through the menu until the LCD reads ‘pH
Control Mode’.
Press OK to enter this mode.
If the setting on the chlorinator has previously been set for the acid dosing system to be ‘ON’ and the
system needs to be turned ‘OFF’ use the following procedure.
To turn OFF the acid dosing of the pH controller, press [OK] on the ‘pH
mode: ON’ menu from ‘pH Control Mode’ menu explained in 10.1.
Then use the [+] or [-] button to change the selection from ON to OFF
and press [OK] to save.
pH CONTROL MODE
pH1 Run Time
pH2 Demand or Prime
[+] UP [-] DN [OK] ENTER
pH DEMAND OR PRIME
Acid Demand: xxxx ml
[+] or [-] to change
[OK] SAVE [<] BACK
13 Winter / Blanket
14 pH Control Mode
[+] UP [-] DN [OK] ENTER
pH CONTROL MODE
pH Mode: ON
[+] or [-] to change
[OK] SAVE [<] EXIT