Troubleshooting
Malfunction
Cause
Remedy
The unit does not switch on
No power supply
•
Check power supply
•
Check supply lines
The hand-held transmitter does
not transmit
•
Insert a new battery
•
Teach-in hand-held transmitter
LED not lit
Connection of the Water Jets
faulty
Check connections
Insufficient fountain height
The running unit device is clogged
or soiled
Clean the running unit
Pump strainer casing soiled
Clean strainer casing
Nozzles soiled
Clean the nozzles
Foam filters soiled
Wash out foam filters
Hose kinked
Lay hose in a sufficiently large bend
Y distributor clogged
Clean Y distributor
Regulator on Y-distributor incor-
rectly set
Adjust regulator
Unit switches off after a brief run-
ning time (approx. 10 s)
Water temperature too high
Note maximum water temperature
of + 95 °F (+35°C). For switching on
again, pull the power plug and rein-
sert in the socket.
Pumps run dry
Check water level. For switching on
again, pull the power plug and rein-
sert in the socket.