Remedy of faults
Malfunction Cause
Remedy
No voltage at output.
Unit is overloaded and has switched off.
Connect consumers with a lower connected
load (
Technical data)
After elimination of the cause, carry out a reset:
Switch off the unit (disconnect the power
plug) and wait for 5 minutes.
Switch on the unit
No or insufficient mains voltage
Provide specified mains voltage (
Technical
Data)
No voltage at a single output
A single output is overloaded
Connect consumers with a lower connected
load (
Technical data)
After elimination of the cause, carry out a reset:
Switch off the unit (disconnect the power
plug) and wait for 5 minutes.
Switch on the unit
Repair
Repair is not possible in the following cases. The class 2 power supply has to be replaced.
If there is no replacement part approved by OASE for a defective component.
Maintenance and cleaning
Attention! Dangerous electrical voltage.
Possible consequences:
Death or severe injury.
Protective measures:
Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
Isolate the unit before starting any work.
Secure the unit to prevent unintentional switching on.
Cleaning the unit
If necessary, clean the unit with clear water using a soft brush.
Unit maintenance
The unit requires regular maintenance. Carry out the work according to the maintenance schedule.
Only allow the maintenance work to be carried out by trained personnel who are qualified for these activities due to
their technical training, knowledge and experience.
Storage/Over-wintering
In case of extreme frost or ice loading, deinstall the unit(
Technical data). Thoroughly clean and check the unit for
damage.