- EN -
77
System message
Functions that are still
available
Possible cause
Remedy
Resetting the system
message
The drum load is distributed une-
venly
•
Align the container horizontally
Pump fed system only:
Water level too low
Ensure that the water level in the drum filter is
280 ... 400 mm below the edge of the container.
Gravity fed systems only:
Excessive difference in water level
inlet side/drum side
•
Determine the cause of the difference and eliminate it
(e.g. level detection device set too low, screens
clogged, rinsing function inactive)
•
Switch off the pumps and wait until the water level is
equal on both sides. Subsequently, switch on the
pumps again and check the difference.
System message
Functions that are still
available
Possible cause
Remedy
Resetting the system
message
Er55
More than 960 cleaning
cycles in 48 hours
•
Manual cleaning
•
Automatic mode
•
Time-dependent
cleaning
•
Extended cleaning time
"Extra Cleaning"
Temporary heavy soiling
•
Start-up phase of the filter system
(e.g. during the first start-up)
•
Fish are spawning
Wait until the soiling decreases
•
This operating status is atypical. Avoid long-term
operation in this state.
−
Press
key for 5 s
−
Automatic if the num-
ber of cleaning proce-
dures drops below 960.
Pond heavily soiled
•
Clean the pond
•
Reduce the amount of soiling
Screen elements heavily soiled
Clean/descale the screen elements (→
Insufficient cleaning effect due to
soiled nozzles
Clean the nozzles
Water level in the system too high:
•
Outlet pipes soiled
•
Outlet opening too small
•
Max. flow rate exceeded
•
Clean outlet pipes
•
Enlarge outlet opening
•
Reduce flow rate
Er66
Switch element for rinsing
pump in the control sys-
tem overheated
None
Control system is exposed to ex-
cessive heat (sun, ambient temper-
ature)
Protect the control system from heat
Automatic when cooled
down
Er88
The filter pump is not
supplying any water or
insufficient water.
•
Manual cleaning
•
Automatic mode
•
Time-dependent
cleaning
•
Extended cleaning time
"Extra Cleaning"
Pump status detection incorrectly
set
Set the pump status detection.
Automatic after elimination
of the cause
The filter pump is switched off.
Switch on the filter pump.
The impeller unit of the filter pump
is blocked.
Clean the filter pump.
Summary of Contents for ProfiClear Premium TF-XL
Page 1: ...ProfiClear Premium TF XL 18171 02 H 18171 GA_Trommelfiltermodul_A5_end 08 02 12 09 21 Seite 2...
Page 2: ...2 Proficlear0224...
Page 3: ...3 ProfiClear0225...
Page 4: ...4 A ProfiClear0198...
Page 5: ...5 B ProfiClear0199...
Page 6: ...6 C ProfiClear0212 D ProfiClear0213...
Page 7: ...7 E ProfiClear0214 F ProfiClear0217 G ProfiClear0216...
Page 8: ...8 H ProfiClear0227...
Page 9: ...9 I ProfiClear0200...
Page 10: ...10 J ProfiClear0228 K ProfiClear0201...
Page 11: ...11 L ProfiClear0226 M ProfiClear0222 N EGC0003 O ProfiClear0047...
Page 12: ...12 P ProfiClear0109 Q R ProfiClear0203 ProfiClear0205 S ProfiClear0204...
Page 13: ...13 T ProfiClear0206...
Page 14: ...14 U ProfiClear0207...
Page 15: ...15 V ProfiClear0210...
Page 16: ...16 W ProfiClear0211 X Y ProfiClear0209 ProfiClear0208...
Page 369: ...RU 369 RU RU 8 30...
Page 372: ...RU 372 1 ProfiClear Premium TF XL EGC 1 1 1 2 A A...
Page 373: ...RU 373 2 2 1 2 2 ICD 20 2 3...
Page 377: ...RU 377 3 5 4 C 35 C A 4 4 1 E U 12 U 12 2 25...
Page 378: ...RU 378 DN 110 4 1 1 F 200 Moving Bed 24 500 500 50 1500 1000 280 400 ProfiClear Premium XL...
Page 379: ...RU 379 4 1 2 G 680 20 20 20 ProfiClear Guard 4 2 4 2 1 45 50 7 7...
Page 381: ...RU 381 4 2 4 A B 110 110 DN 75 DN 75 75 110 110 4 3 EGC K...
Page 383: ...RU 383 4 5 EGC 4 5 1 2 O 1 EGC 2 EGC EGC 4 5 2 P 2 5 OASE PondoVac 24...
Page 384: ...RU 384 Er88 5 1 5 1 1 A 1 2 3 4 5 6 7 8 9 10...
Page 386: ...RU 386 5 2 2 10 R 1 Er11 2 Max Min 3 4 5 6 7 8 9 10 5 2 3 Er88 Er88 Er88 10 Er88 3 5 3 5...
Page 393: ...RU 393 6 8 4 Er11 Er22 12 C 24 Extra Cleaning 5 Er33 20 Extra Cleaning 5 1 8...
Page 395: ...RU 395 280 400 Er55 960 48 Extra Cleaning 5 960 Er66 Er88 E7...
Page 396: ...RU 396 Extra Cleaning...
Page 397: ...RU 397 7 30 24 24 Er22...
Page 398: ...RU 398 Er66 5 20 16 250 8 8 1 PumpClean OASE 8 2...
Page 399: ...RU 399 DN 75 10 8 3 1 2 3 4 DN 75 5 6 7...
Page 400: ...RU 400 8 4 T 1 2 3 4 5 8 5 8 5 1 U 1 180 2 3 1 2 3 4 180...
Page 402: ...RU 402 8 8 X 1 2 8 9 Y 1 2 3 4 9 4 C 20 10 C 8...
Page 405: ...RU 405 ProfiClear Premium V 230 50 12 5 75 A 8 3 2 0 4 231 148 63 14 20 16 A 250...
Page 406: ...CN 406 CN CN 8 30mA...
Page 409: ...CN 409 13 441 14 442...
Page 410: ...CN 410 1 ProfiClear Premium TF XL EGC 1 1 1 2 A A...
Page 411: ...CN 411 2 2 1 2 2 ICD 20 cm 2 3...
Page 415: ...CN 415 3 5 4 C 35 C A 4 4 1 E U 12 V U 12 V 2 m 25 kg...
Page 416: ...CN 416 DN 110 4 1 1 F 200 mm 24 500 500 50 mm 1500 1000 mm 280 400 mm ProfiClear Premium XL...
Page 417: ...CN 417 4 1 2 G 680 mm 20 mm 20 mm 20 mm ProfiClear Guard 4 2 4 2 1 45 50 mm m 7 7...
Page 420: ...CN 420 4 5 EGC 4 5 1 2 O 1 EGC 2 EGC EGC 4 5 2 P 2...
Page 421: ...CN 421 5 OASE PondoVac 24 Er88...
Page 423: ...CN 423 5 2 5 2 1 B 1 2 3 4 5 6 7 120 mm 20 mm 140 mm 8 9 10 11 ProfiClear Premium XL UVC 12 13...
Page 424: ...CN 424 5 2 2 10 mm R 1 Er11 2 3 4 5 6 7 8 9 10...
Page 431: ...CN 431 6 8 4 Er11 Er22 12 C 24 Extra Cleaning 5 Er33 20 Extra Cleaning 5 1 8...
Page 433: ...CN 433 Er55 48 960 Extra Cleaning 5 960 Er66 Er88 Extra Cleaning E7...
Page 434: ...CN 434 7 30 24 24 Er22 Er66 5 20 mm 16 A 250 V...
Page 435: ...CN 435 8 8 1 OASE PumpClean 8 2 DN 75 10 8 3 1 2 UVC 3 4 DN 75 5 6 7...
Page 436: ...CN 436 8 4 T 1 2 3 4 5...
Page 437: ...CN 437 8 5 8 5 1 U 1 180 2 3 4 5 6 7 180 8 5 2 Er33 Er55 Oase 20 25 30 30 1 2 3 4...
Page 438: ...CN 438 8 6 V 1 90 2 SW 5 3 4 5 6 7 8 7 W 1 2 3 OASE Turmsilon GTI 300 GK...
Page 439: ...CN 439 8 8 X 1 2 8 9 Y 1 2 3 4...
Page 440: ...CN 440 9 4 C 20 10 C 8 C 10 OASE 11 12 OASE www oase com ersatzteile...
Page 443: ...CN 443...
Page 444: ...76372 01 21...