4.1.2 Gravity fed system
G
The correct installation and constant water level in the pond are important prerequisites for en-
suring optimum and fault-free operation of the gravity fed system.
Making a filter pit:
•
Excavate a pit of sufficient dimensions to accommodate the filter system.
•
Align the base slab horizontally.
•
Secure the walls of the pit from falling in (with masonry or concrete).
•
Ensure that the pit is protected from flooding. Provide a rain water drain.
Installing the filter system:
•
Determine the max. water level for the pond.
•
The base slab supporting the filter system must be 680 mm below the max. water level (max.
tolerance: -20 mm).
•
Keeping the water level constant:
•
A constant water level in the pond is necessary for operating the gravity fed system. Toler-
ances of up to -20 mm from the max. water level are permitted.
– If the max. water level in the pond is exceeded, water flows out of the drum filter module
via the dirt channel until the max. water level is reached again.
– If the water level goes below the max. water level by more than 20 mm, it is not possible to
achieve optimum or fault-free operation.
•
Recommendation: ProfiClear Guard automatically refills the pond with water, if the water
level drops below the permissible level.
4.2
Connecting the drum filter
4.2.1 Information regarding pipes
•
Use suitable pipes.
•
Do not use any right-angled bends. Bends with a maximum angle of 45° are very efficient.
•
Glue plastic pipes to ensure a permanent and reliable joint or use socket joints with clips to
stop them from coming apart.
•
Standing water in pipes can freeze when there is a hard frost and cause pipes to burst. For
this reason, lay the pipes and hoses with a gradient (50 mm/m) to ensure that they can run
empty.
•
For gravity fed systems, it must be possible to shut off the supply from the pond and the
return to the pond for maintenance and repair work. For this reason, install suitable slide
valves.
•
In the case of the gravity fed system, the sum of the losses in the supply line must not ex-
ceed 7 mbar (7 cm).
– Otherwise the water level in the filter system will go below the minimum water level during
operation. Optimum, fault-free operation will no longer be possible.
Summary of Contents for ProfiClear Premium TF-XL
Page 1: ...ProfiClear Premium TF XL 18171 02 H 18171 GA_Trommelfiltermodul_A5_end 08 02 12 09 21 Seite 2...
Page 2: ...2 Proficlear0224...
Page 3: ...3 ProfiClear0225...
Page 4: ...4 A ProfiClear0198...
Page 5: ...5 B ProfiClear0199...
Page 6: ...6 C ProfiClear0212 D ProfiClear0213...
Page 7: ...7 E ProfiClear0214 F ProfiClear0217 G ProfiClear0216...
Page 8: ...8 H ProfiClear0227...
Page 9: ...9 I ProfiClear0200...
Page 10: ...10 J ProfiClear0228 K ProfiClear0201...
Page 11: ...11 L ProfiClear0226 M ProfiClear0222 N EGC0003 O ProfiClear0047...
Page 12: ...12 P ProfiClear0109 Q R ProfiClear0203 ProfiClear0205 S ProfiClear0204...
Page 13: ...13 T ProfiClear0206...
Page 14: ...14 U ProfiClear0207...
Page 15: ...15 V ProfiClear0210...
Page 16: ...16 W ProfiClear0211 X Y ProfiClear0209 ProfiClear0208...
Page 369: ...RU 369 RU RU 8 30...
Page 372: ...RU 372 1 ProfiClear Premium TF XL EGC 1 1 1 2 A A...
Page 373: ...RU 373 2 2 1 2 2 ICD 20 2 3...
Page 377: ...RU 377 3 5 4 C 35 C A 4 4 1 E U 12 U 12 2 25...
Page 378: ...RU 378 DN 110 4 1 1 F 200 Moving Bed 24 500 500 50 1500 1000 280 400 ProfiClear Premium XL...
Page 379: ...RU 379 4 1 2 G 680 20 20 20 ProfiClear Guard 4 2 4 2 1 45 50 7 7...
Page 381: ...RU 381 4 2 4 A B 110 110 DN 75 DN 75 75 110 110 4 3 EGC K...
Page 383: ...RU 383 4 5 EGC 4 5 1 2 O 1 EGC 2 EGC EGC 4 5 2 P 2 5 OASE PondoVac 24...
Page 384: ...RU 384 Er88 5 1 5 1 1 A 1 2 3 4 5 6 7 8 9 10...
Page 386: ...RU 386 5 2 2 10 R 1 Er11 2 Max Min 3 4 5 6 7 8 9 10 5 2 3 Er88 Er88 Er88 10 Er88 3 5 3 5...
Page 393: ...RU 393 6 8 4 Er11 Er22 12 C 24 Extra Cleaning 5 Er33 20 Extra Cleaning 5 1 8...
Page 395: ...RU 395 280 400 Er55 960 48 Extra Cleaning 5 960 Er66 Er88 E7...
Page 396: ...RU 396 Extra Cleaning...
Page 397: ...RU 397 7 30 24 24 Er22...
Page 398: ...RU 398 Er66 5 20 16 250 8 8 1 PumpClean OASE 8 2...
Page 399: ...RU 399 DN 75 10 8 3 1 2 3 4 DN 75 5 6 7...
Page 400: ...RU 400 8 4 T 1 2 3 4 5 8 5 8 5 1 U 1 180 2 3 1 2 3 4 180...
Page 402: ...RU 402 8 8 X 1 2 8 9 Y 1 2 3 4 9 4 C 20 10 C 8...
Page 405: ...RU 405 ProfiClear Premium V 230 50 12 5 75 A 8 3 2 0 4 231 148 63 14 20 16 A 250...
Page 406: ...CN 406 CN CN 8 30mA...
Page 409: ...CN 409 13 441 14 442...
Page 410: ...CN 410 1 ProfiClear Premium TF XL EGC 1 1 1 2 A A...
Page 411: ...CN 411 2 2 1 2 2 ICD 20 cm 2 3...
Page 415: ...CN 415 3 5 4 C 35 C A 4 4 1 E U 12 V U 12 V 2 m 25 kg...
Page 416: ...CN 416 DN 110 4 1 1 F 200 mm 24 500 500 50 mm 1500 1000 mm 280 400 mm ProfiClear Premium XL...
Page 417: ...CN 417 4 1 2 G 680 mm 20 mm 20 mm 20 mm ProfiClear Guard 4 2 4 2 1 45 50 mm m 7 7...
Page 420: ...CN 420 4 5 EGC 4 5 1 2 O 1 EGC 2 EGC EGC 4 5 2 P 2...
Page 421: ...CN 421 5 OASE PondoVac 24 Er88...
Page 423: ...CN 423 5 2 5 2 1 B 1 2 3 4 5 6 7 120 mm 20 mm 140 mm 8 9 10 11 ProfiClear Premium XL UVC 12 13...
Page 424: ...CN 424 5 2 2 10 mm R 1 Er11 2 3 4 5 6 7 8 9 10...
Page 431: ...CN 431 6 8 4 Er11 Er22 12 C 24 Extra Cleaning 5 Er33 20 Extra Cleaning 5 1 8...
Page 433: ...CN 433 Er55 48 960 Extra Cleaning 5 960 Er66 Er88 Extra Cleaning E7...
Page 434: ...CN 434 7 30 24 24 Er22 Er66 5 20 mm 16 A 250 V...
Page 435: ...CN 435 8 8 1 OASE PumpClean 8 2 DN 75 10 8 3 1 2 UVC 3 4 DN 75 5 6 7...
Page 436: ...CN 436 8 4 T 1 2 3 4 5...
Page 437: ...CN 437 8 5 8 5 1 U 1 180 2 3 4 5 6 7 180 8 5 2 Er33 Er55 Oase 20 25 30 30 1 2 3 4...
Page 438: ...CN 438 8 6 V 1 90 2 SW 5 3 4 5 6 7 8 7 W 1 2 3 OASE Turmsilon GTI 300 GK...
Page 439: ...CN 439 8 8 X 1 2 8 9 Y 1 2 3 4...
Page 440: ...CN 440 9 4 C 20 10 C 8 C 10 OASE 11 12 OASE www oase com ersatzteile...
Page 443: ...CN 443...
Page 444: ...76372 01 21...