- EN -
7
Correct electrical installation
Electrical installations must meet the national regulations and may only be carried out by a qualified electrician.
A person is regarded as a qualified electrician if, due to his/her vocational education, knowledge and experience, he
or she is capable of and authorised to judge and carry out the work commissioned to him/her. This also includes the
recognition of possible hazards and the adherence to the pertinent regional and national standards, rules and regula-
tions.
For your own safety, please consult a qualified electrician.
The device may only be connected if the electrical data of the device and the power supply coincide. The device data
is to be found on the device type plate, on the packaging or in this manual.
Ensure that the unit is fused for a rated fault current of max. 30
mA by means of a fault current protection device.
Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use (splash-proof).
Protect the plug connections from moisture.
Only plug the unit into a correctly fitted socket.
Safe operation
Never operate the unit if either the electrical cables or the housing are defective!
Do not carry or pull the unit by its electrical cable.
Route cables/hoses such that they are protected from damage and do not present a tripping hazard.
Only open the unit housing or its attendant components, when this is explicitly required in the operating instructions.
Only carry out work on the unit that is described in this manual. If problems cannot be overcome, please contact an
authorised customer service point or, when in doubt, the manufacturer.
Only use original spare parts and accessories for the unit.
Never carry out technical modifications to the unit.
Power connection cables cannot be replaced. If a cable is damaged, dispose of the respective unit or components.
Only operate the unit if no persons are in the water.
Keep the socket and power plug dry.
The impeller unit in the pump contains a magnet with a strong magnetic field that may affect the operation of pace-
makers or implantable cardioverter defibrillators (ICDs). Always keep magnets at least 20 cm away from implanted
devices.
Installation
A
Cut the stepped hose adapters such that the connection opening coincides with the hose diameter. This helps to avoid
pressure loss.
At the filter pump, push or turn the hose onto the stepped hose connection, secure with hose clips and screw onto the
filter pump connection thread.
Installation
Place the unit in the pond horizontally on firm, sludge-free ground and ensure that it is completely covered with water
at a maximum of 4 m below the surface of the water.
Commissioning/start-up
Sensitive electrical components.
Possible consequences:
The device will be destroyed.
Protective measure:
Do not connect the unit to a dimmable power supply.
Attention! The pump must never run dry.
Possible consequence:
The pump will be destroyed.
Protective measure:
Check the water level at regular intervals. Always place the unit below water level.
Attention!
Risk of injury due to unexpected start-up.
The temperature monitor switches the unit off automatically in the event of overload. The unit is switched on
again automatically as soon as it has cooled down.
Possible consequences:
Risk of injury due to fast rotating components.
Protective measures:
Always isolate the unit (switch off and disconnect from the power supply) before start-
ing any work on the unit.
This is how to connect the power supply:
Switching on:
Connect the unit to the mains. The unit switches on as soon as the power connection is established.
Switching off:
Disconnect the unit from the mains.