Pos: 127 /Alle Produkte/Überschriften/H1 Bedienung @ 7\mod_1196625148604_121.doc @ 41443 

 

8. Operation 

Pos: 128 /Filter/FiltoMatic CWS/Bedienung_FiltoMatic_CWS_Controller @ 9\mod_1228742430209_121.doc @ 57959 

 

8.1 Controller 

overview 

 

 

C1 Display 

C2 

LED displaying the dirty water 
pump function 

C3 

LED displaying the UVC 
function 

C4 

Key for manual dirty water 
pump operation 

C5 

Key for setting a cleaning 
program for the dirty water 
pump 

 

C6 

Key for setting an operating 
program for the UVC clarifying 
unit 

Displays on the controller 

 

Display (C1) 

 

Water temperature as standard 

 

Cleaning program as selected 

 

Saved settings 

 

Operating hour counter (h

±

100) 

 

switches automatically back to temperature display 2 seconds after the last key actuation 

 

LED for dirty water pump (C2) 

 

LED flashes green: Partial container drainage 

 

LED is lit green: complete container drainage 

 

LED is lit red: Pump blocked 

 

LED off: Pump not active 

 

LED for UVC clarifying unit (C3) 

 

LED is lit blue: UVC clarifying unit is switched on 

 

LED flashes blue in a 8 second interval: The UVC clarifying unit is integrated in the Automatic (AU) operating program 

 

LED flashes in a 1 second interval: The UVC lamp was active for 7500 operating hours; remaining operating life: 500 operating 
hours 

 

LED flashes twice each half second and once for one second: UVC lamp has reached 8000 operating hours 

 

LED off: UVC clarifying unit is switched off 

 

Note: 
The integrated thermometer permanently measures the water temperature, thereby forming the reference value for the operating 
programs. 
The silicone cover protects the controller from soiling; it impairs neither the display reading nor the functionality of the keys. The 
controller is water tight and can also be operated without the silicone cover. 

 

 

Moisture can collect in the transparent gap of the controller. This moisture is negligible and does not 
affect the controller function. 

 

Pos: 129 /Filter/FiltoMatic CWS/Bedienung_FiltoMatic_CWS_Schmutzwasserpumpe_einstellen @ 9\mod_1228742517131_121.doc @ 57987 

 

8.2 

Setting the dirty water pump 

As the water temperature, the degree of soiling of the pond water greatly depends on the fish 
population. The dirty water pump pumps out the dirt from the container bottom in intervals. The four 
different cleaning programs allow to individually adapt the interval for pumping off the dirty water to the 
degree of soiling. A cleaning cycle takes approx. 8 seconds. Approx. 5 litres of pond water are required 
for one cleaning cycle. The table shows the cleaning program selection options. The cleaning program 

INTERVAL 1

 includes the majority of cleaning intervals, 

INTERVAL 4

 the smallest number of intervals. 

Select a program that is best suited for the degree of soiling of the pond water. When delivered, cleaning 
program 

INTERVAL 2

 is set as a default. 

 

Cleaning programs, dirty water pump 

+

 Intervals  

  

 Intervals 

Water temperature 

INTERVAL 1 

INTERVAL 2 

INTERVAL 3 

INTERVAL 4 

OF 

<

 5 °C 

off off off off off 

<

 8 °C 

1 × per day 

every 2 days 

every 3 days 

every 3 days 

off 

8 °C - 14 °C 

2 × per day 

1 × per day 

every 2 days 

every 3 days 

off 

15 °C - 21 °C 

4 × per day 

2 × per day 

1 × per day 

every 2 days 

off 

 22 °C 

8 × per day 

4 × per day 

2 × per day 

1 × per day 

off 

 
 

 

The cleaning programs are inactive at a water temperature of 

<

 5 °C. The pump can then only be 

actuated manually. For fully pumping out, keep the PUMP 

(C4) 

key permanently pressed. 

 

Summary of Contents for FiltoMatic CWS

Page 1: ...FiltoMatic CWS...

Page 2: ...2 Pos 2 Filter FiltoMatic CWS Grafik_mon1_FiltoMatic_CWS 9 mod_1225900315094_0 doc 55281 Pos 3 Filter FiltoMatic CWS Grafik_mon2_FiltoMatic_CWS 9 mod_1228948908636_0 doc 58191...

Page 3: ...3 Pos 4 Filter FiltoMatic CWS Grafik_mon3_FiltoMatik_CWS 9 mod_1228949046309_0 doc 58218...

Page 4: ...4 Pos 5 Filter FiltoMatic CWS Grafik_mon4_FiltoMatic_CWS 9 mod_1228949149325_0 doc 58245...

Page 5: ...5 Pos 6 Filter FiltoMatic CWS Grafik_mon5_FiltoMatic_CWS 9 mod_1228949238169_0 doc 58272...

Page 6: ...6 Pos 7 Alle Produkte L nderkennzeichen 00 LEER 0 mod_1126786111024_0 doc 5631 Pos 8 Alle Produkte Dummy_module Seitenwechsel 0 mod_1125648978015_0 doc 1630...

Page 7: ...itions 20 3 1 Intended use 20 3 2 Use other than that intended 20 3 3 Extended guarantee conditions for the OASE ClearWaterSystem 20 3 4 CE Manufacturer s Declaration 20 4 Safety information 21 4 1 Ha...

Page 8: ...filter system for the mechanical and biological cleaning of garden ponds having a water temperature of between 4 C and 35 C The unit is exclusively suited for private use and may only be employed for...

Page 9: ...a correctly fitted socket Please note that the power supply must be fused via a fault current protection system with a maximum reference fault current of 30 mA Install the FiltoMatic CWS such that any...

Page 10: ...lation of FiltoMatic CWS Figure D Take into consideration that the FiltoMatic CWS can be buried up to the top recess Figure E height c Please use the following table as a basis for the pit dimensions...

Page 11: ...iebnahme FiltoMatic CWS 9 mod_1225196867060_121 doc 54865 Attention Dangerous electrical voltage Possible consequences Death or severe injury Protective measures Disconnect the power plug Figure G pri...

Page 12: ...roller from soiling it impairs neither the display reading nor the functionality of the keys The controller is water tight and can also be operated without the silicone cover Moisture can collect in t...

Page 13: ...is switched on UVC lamp is switched off 8 C 8 h 16 h 8 C 14 C 48 h 24 h 15 C 21 C 72 h 24 h 22 C 96 h 24 h UVC lamp is permanently switched on UVC lamp is permanently switched off When delivered the...

Page 14: ...te the cleaning components from each other For cleaning and maintenance of the cleaning components of the dirty water pump 14 and the UVC clarifying unit 16 it is necessary to take both out of the con...

Page 15: ...mp by looking into the control window 18 at regular intervals Figure O The operating life of the UVC lamp being limited it has to be replaced once its useful life has elapsed please also refer to Chap...

Page 16: ...ss the PUMP key C4 on the controller 15 for longer than 10 seconds Figure J The LED C2 is lit green The dirty water in the container will be pumped out 5 Lift the cleaning components of the dirty wate...

Page 17: ...k An approx 8 mm spacing is provided between the dirt pyramid 53 and the container bottom This gap allows the dirty water pump to pump off the dirt gathered at the container bottom Take this spacing i...

Page 18: ...reset the safety system Check that the UVC lamp is lit in the control window blue light To test we suggest to switch on the UVC lamp using the UVC key operating status ON Pos 148 Alle Produkte Dummy_m...

Page 19: ...eit Temperaturf hler Teichvolumen ohne Fischbesatz Teichvolumen mittlerer Fischbesatz Teichvolumen hoher Fischbesatz Wasseraufnahme Beh lter Betriebsdruck max Durchfluss min Durchfluss GB Technical da...

Page 20: ...ects du soleil Retirer l appareil en cas de gel Ne pas recycler dans les ordures m nag res Attention Lire la notice d emploi NL Stofdicht Waterdicht tot een diepte van 2 m Let op Gevaarlijke UVC stral...

Page 21: ...81 Pos 452 Filter FiltoMatic CWS Ersatzteile 1 FiltoMatic CWS 9 mod_1231340063791_0 doc 59211 Pos 453 Filter FiltoMatic CWS Ersatzteile 2 FiltoMatic CWS 9 mod_1231340403874_0 doc 59238...

Page 22: ...82 Pos 454 Filter FiltoMatic CWS Ersatzteile 3 FiltoMatic CWS 9 mod_1231340506633_0 doc 59265...

Page 23: ...83 Pos 455 Alle Produkte Dummy_module Seitenwechsel 0 mod_1125648978015_0 doc 1630...

Reviews: