23
- GB -
Installation of the inlet (Figure F)
1. Plug the inlet sheath
(9)
and the flat sealing
(6)
into the union nut
(10)
and tighten at the stop valve
thread
(21)
.
2. Slide the hose clip
(11)
over the hose
(24)
arriving from the Aquamax. Push the hose on the inlet
sheath
(9)
and fasten with the hose clip.
Hose recommended by OASE: Spiral hose, green (OASE Order No. 52981)
Prior to the assembly, place the hose end in hot water for two minutes. It will then be easier to slide the
hose onto the inlet sheath
(9)
.
Installation of the dirty water outlet (Figure F)
1. Fit the O ring
(7)
on the outlet sheath
(8)
and into the union nut
(10)
. Then tighten to the thread of
the pre-assembled dirty water outlet
(22)
.
2. Plug a DN40 pipe
(23)
onto the outlet sheath
(8)
. Route the end of the DN40 pipe to a point where
the dirty water to be pumped out can trickle into the ground. Ensure a gravity of 1.5 % to 2 % for the
DN40 pipe.
As an extension for the dirty water outlet, OASE recommends the following:
−
DN40 pipe, 480 mm, black (OASE Order No. 50307)
−
DN40 pipe elbow, 45°, black (OASE Order No. 50308)
Pos: 123 /Alle Produkte/Dummy_module/Abstand 18 pt @ 6\mod_1196355593257_0.doc @ 41089
Pos: 124 /Alle Produkte/Überschriften/H1 Inbetriebnahme @ 7\mod_1196625111244_121.doc @ 41417
7. Start-up
Pos: 125 /Filter/FiltoMatic CWS/Inbetriebnahme FiltoMatic CWS @ 9\mod_1225196867060_121.doc @ 54865
Attention!
Dangerous electrical voltage.
Possible consequences:
Death or severe injury.
Protective measures:
Disconnect the power plug
(Figure G)
prior to reaching into the water and
commencing work.
Follow the safety information!
The FiltoMatic CWS switches on automatically when the power connection is established.
Switching on (Fig. G):
Plug the power plug
(27)
into the socket.
Switching off (Fig. G):
Disconnect the power plug
(27)
.
Fill the container with water (Figure C)
►
Switch the Aquamax pump on prior to commissioning the FiltoMatic CWS. Container
(3)
has to be
filled with water.
Stop valve
(17)
needs to be open to enable the container to be filled. For this purpose, press the stop
valve
(17)
down against the stop.
As soon as the water level in the container
(3)
reaches the outlet
(4)
, the filtered pond water returns into
the pond via the outlet
(4)
.
For further settings of the FiltoMatic CWS, please read the following Chapter
Operation
.
Filling with biological filter starter (Figure C)
We recommend the OASE filter starter Biokick CWS (OASE Order No. 50295) for a fast growth of
bacteria populations. Micro-organisms colonise the filter system, multiply and ensure an enhanced
quality of the pond water by the decomposition of excess nutrients.
►
Fill the quantity of Biokick CWS sufficient for the volume of your pond into the infill opening
(20)
.
Pos: 126 /Alle Produkte/Dummy_module/===== Seitenwechsel ===== @ 0\mod_1125648978015_0.doc @ 1631
Summary of Contents for FiltoMatic CWS
Page 1: ...FiltoMatic CWS...
Page 3: ...3 Pos 4 Filter FiltoMatic CWS Grafik_mon3_FiltoMatik_CWS 9 mod_1228949046309_0 doc 58218...
Page 4: ...4 Pos 5 Filter FiltoMatic CWS Grafik_mon4_FiltoMatic_CWS 9 mod_1228949149325_0 doc 58245...
Page 5: ...5 Pos 6 Filter FiltoMatic CWS Grafik_mon5_FiltoMatic_CWS 9 mod_1228949238169_0 doc 58272...
Page 22: ...82 Pos 454 Filter FiltoMatic CWS Ersatzteile 3 FiltoMatic CWS 9 mod_1231340506633_0 doc 59265...
Page 23: ...83 Pos 455 Alle Produkte Dummy_module Seitenwechsel 0 mod_1125648978015_0 doc 1630...