background image

28

 

- GB - 

 

Pos: 139 /Filter/FiltoMatic CWS/Reinigung_Wartung_FiltoMatic_CWS_Reinigungsrotor_kontrollieren @ 9\mod_1228741419030_121.doc @ 57875 

 

9.5 

Checking the cleaning rotor 

The cleaning rotor 

(37)

 cleans the quartz glass tube 

(45)

. The rotor is driven by the water flow in the 

water housing 

(Figure P)

The constant rotational movement of the cleaning rotor 

(37)

 causes wear of the bearing bush 

(38)

. In 

this case, the cleaning rotor 

(37)

 needs replacing 

(Figure P)

1.  Turn the water housing 

(35)

 until the symbol showing " Lock open" points to the arrow at the UVC top 

pipe 

(34) (Figure O)

2.  Pull off the water housing 

(35)

 

(Figure O)

3.  Check the wearing condition of the bearing bush 

(38)

 

When the bearing bush 

(38)

 has worn down to 0 mm, the cleaning rotor 

(37)

 needs to be 

replaced 

(Figure P)

4.  Reassemble the UVC clarifying unit in the reverse order. 

 

Important: The water housing 

(35)

 is only closed when the "Lock closed" symbol points to the 

arrow on the UVC top section 

(34)

 

(Figure O)

Pos: 140 /Filter/FiltoMatic CWS/Reinigung_Wartung_FiltoMatic_CWS_Filterschaeume_wechseln @ 9\mod_1228741505640_121.doc @ 57903 

 

 

9.6 

Changing the foam filters 

We recommend to change the foam filters 

(49)

 once a year, or whenever a gap forms between the foam 

filter 

(49)

 and the inner cover 

(47)

How to change the foam filters: 

1.  

Open lid 

(1)

 with the rotary handle 

(2)

 and remove lid from the container 

(3)

 

(Figure H)

2.  Close stop valve 

(17)

 by pulling it up 

(Figure S)

 

Pond water no longer flows into the container. 

 

Note: Water will spurt out of the air intake socket when closing the stop valve 

(17)

3.  Pull up the foam holder 

(13)

 in the inner cover 

(47)

 three times. The water in the foam filters 

(49)

 is 

pressed out 

(Figure I)

4.  Press the PUMP key 

(C4)

 on the controller 

(15)

 for longer than 10 seconds 

(Figure J)

   

The LED 

(C2)

 is lit green. The dirty water in the container will be pumped out. 

5.

 

  Lift the cleaning components of the dirty water pump 

(14)

 and of the UVC clarifying unit 

(16)

 out of 

the inner cover 

(47)(Figure K)

6.  Release the blue engagement hooks 

(19)

 on both sides, then remove the inner cover 

(47)

 including 

the foam holders 

(13)

 out of the container 

(Figure S)

7.  Slightly lift the foam holder 

(13)

 by pulling, press in the blue engagement hooks 

(48)

 at the foam 

holders 

(13)

, then take out the foam holders 

(13)

 downward 

(Figure T)

8.  

Pull the used foam filters 

(49)

 over the handle of the foam holder 

(12)

 by pulling and insert new foam 

filters 

(49)

 in the opposite order 

(Figure U)

9.  Insert the foam filters in the reverse order. 

 

Pos: 141 /Filter/FiltoMatic CWS/Reinigung_Wartung_FiltoMatic_CWS_Komplettreinigung_durchfuehren @ 9\mod_1228741615703_121.doc @ 57931 

 

9.7 

Thorough cleaning of the unit 

Light-weight suspended matter is mechanically filtered by the foam filters and, if necessary, biologically 
broken down. Suspended matter heavier than water will sediment out and soil the container bottom.  
Thoroughly clean the unit once per year, preferably when you prepare the FiltoMatic CWS for the winter. 

 

Fully drain the container 

Full drainage takes a maximum of 4 minutes. 

1.  Switch off the Aquamax pump. 

2.  Open lid (1) with the rotary handle (2) and remove lid from the container (3) 

(Figure H)

3.  Pull up the foam holder 

(13)

 three times 

(Figure J)

 

The foam filters will be compressed. The soiling will be washed out. 

4.  

Press the PUMP 

(C4)

 key for longer than 10 seconds. 

 

The LED 

(C2)

 is lit green. The container is emptied. 

 

You can stop the drainage cycle by pressing the PUMP 

(C4)

 key once. Once the container if fully 

drained, when the dirty water pump switches off no water flows through the transparent outlet 
sheath 

(6)

 

 

Summary of Contents for FiltoMatic CWS

Page 1: ...FiltoMatic CWS...

Page 2: ...2 Pos 2 Filter FiltoMatic CWS Grafik_mon1_FiltoMatic_CWS 9 mod_1225900315094_0 doc 55281 Pos 3 Filter FiltoMatic CWS Grafik_mon2_FiltoMatic_CWS 9 mod_1228948908636_0 doc 58191...

Page 3: ...3 Pos 4 Filter FiltoMatic CWS Grafik_mon3_FiltoMatik_CWS 9 mod_1228949046309_0 doc 58218...

Page 4: ...4 Pos 5 Filter FiltoMatic CWS Grafik_mon4_FiltoMatic_CWS 9 mod_1228949149325_0 doc 58245...

Page 5: ...5 Pos 6 Filter FiltoMatic CWS Grafik_mon5_FiltoMatic_CWS 9 mod_1228949238169_0 doc 58272...

Page 6: ...6 Pos 7 Alle Produkte L nderkennzeichen 00 LEER 0 mod_1126786111024_0 doc 5631 Pos 8 Alle Produkte Dummy_module Seitenwechsel 0 mod_1125648978015_0 doc 1630...

Page 7: ...itions 20 3 1 Intended use 20 3 2 Use other than that intended 20 3 3 Extended guarantee conditions for the OASE ClearWaterSystem 20 3 4 CE Manufacturer s Declaration 20 4 Safety information 21 4 1 Ha...

Page 8: ...filter system for the mechanical and biological cleaning of garden ponds having a water temperature of between 4 C and 35 C The unit is exclusively suited for private use and may only be employed for...

Page 9: ...a correctly fitted socket Please note that the power supply must be fused via a fault current protection system with a maximum reference fault current of 30 mA Install the FiltoMatic CWS such that any...

Page 10: ...lation of FiltoMatic CWS Figure D Take into consideration that the FiltoMatic CWS can be buried up to the top recess Figure E height c Please use the following table as a basis for the pit dimensions...

Page 11: ...iebnahme FiltoMatic CWS 9 mod_1225196867060_121 doc 54865 Attention Dangerous electrical voltage Possible consequences Death or severe injury Protective measures Disconnect the power plug Figure G pri...

Page 12: ...roller from soiling it impairs neither the display reading nor the functionality of the keys The controller is water tight and can also be operated without the silicone cover Moisture can collect in t...

Page 13: ...is switched on UVC lamp is switched off 8 C 8 h 16 h 8 C 14 C 48 h 24 h 15 C 21 C 72 h 24 h 22 C 96 h 24 h UVC lamp is permanently switched on UVC lamp is permanently switched off When delivered the...

Page 14: ...te the cleaning components from each other For cleaning and maintenance of the cleaning components of the dirty water pump 14 and the UVC clarifying unit 16 it is necessary to take both out of the con...

Page 15: ...mp by looking into the control window 18 at regular intervals Figure O The operating life of the UVC lamp being limited it has to be replaced once its useful life has elapsed please also refer to Chap...

Page 16: ...ss the PUMP key C4 on the controller 15 for longer than 10 seconds Figure J The LED C2 is lit green The dirty water in the container will be pumped out 5 Lift the cleaning components of the dirty wate...

Page 17: ...k An approx 8 mm spacing is provided between the dirt pyramid 53 and the container bottom This gap allows the dirty water pump to pump off the dirt gathered at the container bottom Take this spacing i...

Page 18: ...reset the safety system Check that the UVC lamp is lit in the control window blue light To test we suggest to switch on the UVC lamp using the UVC key operating status ON Pos 148 Alle Produkte Dummy_m...

Page 19: ...eit Temperaturf hler Teichvolumen ohne Fischbesatz Teichvolumen mittlerer Fischbesatz Teichvolumen hoher Fischbesatz Wasseraufnahme Beh lter Betriebsdruck max Durchfluss min Durchfluss GB Technical da...

Page 20: ...ects du soleil Retirer l appareil en cas de gel Ne pas recycler dans les ordures m nag res Attention Lire la notice d emploi NL Stofdicht Waterdicht tot een diepte van 2 m Let op Gevaarlijke UVC stral...

Page 21: ...81 Pos 452 Filter FiltoMatic CWS Ersatzteile 1 FiltoMatic CWS 9 mod_1231340063791_0 doc 59211 Pos 453 Filter FiltoMatic CWS Ersatzteile 2 FiltoMatic CWS 9 mod_1231340403874_0 doc 59238...

Page 22: ...82 Pos 454 Filter FiltoMatic CWS Ersatzteile 3 FiltoMatic CWS 9 mod_1231340506633_0 doc 59265...

Page 23: ...83 Pos 455 Alle Produkte Dummy_module Seitenwechsel 0 mod_1125648978015_0 doc 1630...

Reviews: