29
- GB -
Cleaning the unit
For this purpose, remove the lamella separator
(51)
and the dirt pyramide
(52)
. To this effect, completely
empty the container and remove the inner cover
(47)
. Please refer to the chapters above.
How to remove and clean the lamella separator
1. Press down the engagement hook
(50)
and pull the lamella separator
(51)
upward and out of the the
guide on the container
(3)
(Figure V)
.
2. Press in the engagement hook
(52)
at the lamella separator top
(51)
and fold out both sections of
the lamella separator
(51)
(Figure W)
.
3. Clean both parts using clean water and a soft brush.
4. Reassemble the lamella separator
(51)
in the reverse order
5. Insert the lamella separator
(51)
in the container
(3)
(Figure X)
.
−
Ensure that the engagement hook
(50)
engages at the stop valve
(17)
.
How to remove and clean the dirt pyramid (Figure X)
Only remove the dirt pyramid
(53)
if necessary. A great deal of force is required for disassembly and re-
assembly.
1. Reach beneath the dirt pyramid
(53)
and detach the pyramid from the three holders at the container
bottom by vigorously pulling up.
2. Clean the dirt pyramid
(53)
using water and a soft brush.
3. Wash out the container bottom.
4. Plug the dirt pyramid
(53)
onto the holders by applying a large amount of pressure.
−
The engagement in the holders is audible by a click.
An approx. 8 mm spacing is provided between the dirt pyramid
(53)
and the container bottom. This gap
allows the dirty water pump to pump off the dirt gathered at the container bottom. Take this spacing into
account during assembly. Do not attempt to press the dirt pyramid
(53)
fully down to the container
bottom by applying excessive force!
Pos: 142 /Alle Produkte/Dummy_module/Abstand 18 pt @ 6\mod_1196355593257_0.doc @ 41089
Pos: 143 /Alle Produkte/Überschriften/H1 Lagern / Überwintern @ 7\mod_1196625251745_121.doc @ 41495
10. Storage/Over-wintering
Pos: 144 /Filter/FiltoMatic CWS/Lagern/Ueberwintern FitoMatic CWS @ 9\mod_1228336791422_121.doc @ 57733
Prior to the period of frost starting, store the cleaning units dirty water pump
(14)
, controller
(15)
and
UVC clarifying unit
(16)
in a frost-free place.
1. Thoroughly clean all components (see chapter
Carry out complete cleaning
) and check all
components for damage.
−
The container
(3)
and the foam filters
(49)
need not be stored frost-free. However, completely
empty the container
(3)
prior to storing using the pump.
2. Cover the container
(3)
to prevent the ingress of water.
−
The lid
(1)
being closed is not sufficient, as water can enter the container through the recess
provided for the controller.
OASE recommends the following cover:
−
FiltoMatic Cap, size L, for FiltoMatic 3000 CWS and 6000 CWS (OASE Order No. 50268)
−
FiltoMatic Cap, size XL, for FiltoMatic 12000 CWS (OASE Order No. 50269)
Pos: 145 /Alle Produkte/Dummy_module/===== Seitenwechsel ===== @ 0\mod_1125648978015_0.doc @ 1631
Summary of Contents for FiltoMatic CWS
Page 1: ...FiltoMatic CWS...
Page 3: ...3 Pos 4 Filter FiltoMatic CWS Grafik_mon3_FiltoMatik_CWS 9 mod_1228949046309_0 doc 58218...
Page 4: ...4 Pos 5 Filter FiltoMatic CWS Grafik_mon4_FiltoMatic_CWS 9 mod_1228949149325_0 doc 58245...
Page 5: ...5 Pos 6 Filter FiltoMatic CWS Grafik_mon5_FiltoMatic_CWS 9 mod_1228949238169_0 doc 58272...
Page 22: ...82 Pos 454 Filter FiltoMatic CWS Ersatzteile 3 FiltoMatic CWS 9 mod_1231340506633_0 doc 59265...
Page 23: ...83 Pos 455 Alle Produkte Dummy_module Seitenwechsel 0 mod_1125648978015_0 doc 1630...