EN
‐
9
INSTALLATION
AND
CONNECTION
N O T E
Ensure
that
the
pump
never
runs
dry!
Possible
consequences:
The
pump
will
be
destroyed.
Protective
measure:
Regularly
check
the
water
level
in
the
aquarium.
N O T E
Thoroughly
rinse
out
all
filter
material
with
warm
tap
water
before
using
for
the
first
time
in
order
to
remove
any
soiling.
(→ Cleaning
or
replacing
the
filter
media)
D,
E,
B
The
supplied
suction
cups
serve
for
fastening
the
unit
to
a
clean,
smooth
surface.
Push
the
suction
cups
into
the
mounting
holes
of
the
pump
unit
with
a
twisting
movement.
–
Pay
attention
to
the
alignment
of
the
tab
(it
should
point
upwards
or
to
the
side).
Fasten
the
unit
in
a
corner
of
the
aquarium:
Ensure
that
the
flow
‐
out
nozzles
are
just
below
the
surface
of
the
water.
COMMISSIONING/START
‐
UP
E,
B
Route
each
power
connection
cable
such
that
it
forms
a
drip
loop.
BioPlus
Thermo:
Adjust
the
temperature
at
the
thermo
‐
control
heater
HeatUp
(separately
enclosed
instructions).
Switching
on:
Connect
the
unit
to
the
mains.
The
unit
switches
on
immediately.
When
the
unit
is
plugged
in
,
it
takes
several
minutes
for
the
air
to
escape
from
the
unit
(this
makes
a
noise).
Use
the
outlet
control
knob
to
determine
which
wa
‐
ter
outlet
is
used
(central
outlet
or
flow
‐
out
noz
‐
zles).
Switching
off:
Disconnect
the
unit
from
the
mains.
TROUBLESHOOTING
Malfunction
Cause
Remedy
The
unit
does
not
start
up
No
mains
voltage
Check
the
mains
voltage.
Impeller
unit
blocked
Clean
Water
flow
insufficient
Filter
housing
or
impeller
unit
soiled
Clean
Impeller
unit
worn
Replace
impeller
unit
Central
outlet
or
flow
‐
out
nozzles
soiled
Clean
Foam
filter
or
filter
fleece
soiled
Clean
Insufficient
filtering
performance Foam
filter
or
filter
fleece
soiled
Clean
Foam
filter
or
filter
fleece
worn
Replace
Filter
housing
clogged
Clean
the
filter
housing.
Only
BioPlus
Thermo
Insufficient
water
heating
Heater
defective,
not
calibrated
or
temperature
incor
‐
rectly
set.
Replace,
reset
or
calibrate.
Function
description
B
Path
of
the
water:
Drawn
in
by
a
pump
into
the pump unit,
the
water
flows
through
the
filter
modules,
arranged
above
each
other
in
stages
to
form
the
filter
unit.
Each
filter
module
is
equipped
with
a
foam
filter
and/or
filter
fleece
(top
filter
module).
The
water
enters
the
filter
module
through
the
inlet
on
the
side
and
exits
through
the
small
flow
‐
out
nozzles
or
the
central
outlet,
depending
on
the
position
of
the
outlet
control
knob.
BioPlus
Thermo:
The
water
is
heated
by
a
heater
on
its
way
through
the
filter
unit.
Retrofitting
C
By
additionally
purchasing
an
OASE
heater
HeatUp
it
is
possible
to
extend
BioPlus
to
BioPlus
Thermo.
After
removal
of
the
cap,
insert
the
selected
HeatUp (see
following
table),
which
is
suitable
for
the
BioPlus
and
the
size
of
the
aquarium,
into
the
heater
chamber.
A rubber stopper secures
the heater.
HeatUp
25
50
100 150 200
Bio
Plus
50
—
—
—
100
—
—
200
:
Suitable
:
Particularly
recommended
•
BioPlus:
Water
filtering
and
recirculation
•
BioPlus
Thermo:
Water
heating,
filtering
and recirculation.
•
Operation
under
observance
of
the
technical
data.
The
following
restrictions
apply
to
the
unit:
•
Only
use
indoors
and
for
aquaristic
purposes
in
the
home
(not
for
commercial
use).
•
Only
operate
with
water
at
a
water
temperature
of
+39
°F
to
+95
°F.
Additional
information
A
Reference
to
a
figure,
e.g.
Fig.
A.
PRODUCT
DESCRIPTION
Intended
use
BioPlus 50/100/200, BioPlus Thermo 50/100/200 ,
referred
to
in
the
following
as
"unit",
may
only
be
used
as
specified
in
the
following:
Symbols used in these instructions
N O T E
Indicates
information
intended
to
give
the
user
a
bet
‐
ter
understanding.