background image

10

 

BioPlus 50/100/200, BioPlus Thermo 50/100/200 

Pump

 

unit

 

maintenance

 

 

G

 

Remove

 

the

 

pump

 

unit.

 

Release

 

the

 

suction

 

cups

 

with

 

the

 

aid

 

of

 

the

 

tab.

Pull

 

up

 

the

 

nozzle

 

unit

 

and

 

separate

 

it

 

from

 

the

 

base

 

plate.

 

Clean

 

the

 

central

 

outlet

 

and

 

flow

out

 

nozzles.

 

Reassemble

 

the

 

unit

 

in

 

the

 

reverse

 

order.

 

H

 

Pull

 

the

 

pump

 

lid

 

off

 

downward.

Remove

 

the

 

impeller

 

unit,

 

clean

 

or

 

replace.

Reassemble

 

the

 

unit

 

in

 

the

 

reverse

 

order.

 

Ensure

 

that

 

the

 

two

 

rubber

 

bearings

 

are

 

correctly

seated.

 

Re

installing

 

the

 

unit

 

Fit

 

the

 

pump

 

unit

 

and

 

filter

 

unit

 

together

 

again,

 

and

 

install

 

and

 

connect

 

as

 

before

 

in

 

the

 

aquarium

 

(→ Installation

 

and

 

connection):

 

Flow

out

 

nozzles

 

just

 

below

 

the

 

surface

 

of

 

the

water

 

Outlet

 

control

 

knob

 

adjusted

 

as

 

required

 

Power

 

connection

 

cables

 

with

 

drip

 

loop

WEAR

 

PARTS

 

The

 

following

 

components

 

are

 

wear

 

parts

 

and

 

are

 

ex

cluded

 

from

 

the

 

warranty:

 

Filter

 

fleece

Foam

 

filter

Suction

 

cups

Impeller

 

unit

 

‐  

EN

  ‐ 

DISPOSAL

 

Do

 

not

 

dispose

 

of

 

this

 

unit

 

with

 

domestic

 

waste!

 

For

 

disposal

 

purposes,

 

please

 

use

 

the

 

return

 

system

 

pro

vided.

 

Render

 

the

 

unit

 

unusable

 

beforehand

 

by

 

cutting

 

 

the

 

cables.

 

SPARE PARTS

The use of original parts from OASE ensures continued 

safe and reliable operation of the unit. Please visit our 

website for spare parts drawings and spare parts. 

https://www.oase-livingwater.com

 

MAINTENANCE

 

AND

 

CLEANING

 

For

 

cleaning

 

and

 

maintenance,

 

first

 

separate

 

the

 

filter

 

unit

 

from

 

the

 

pump

 

unit

 

and

 

then

 

remove

 

both

 

units

 

from

 

the

 

water.

 

Maintenance

 

of

 

the

 

pump

 

unit

 

involves

 

cleaning

 

the

 

central

 

outlet,

 

flow

out

 

nozzles

 

and

 

impeller

 

unit.

 

If

 

necessary,

 

clean

 

with

 

clear

 

water

 

using

 

a

 

soft

brush.

 

Do

 

not

 

use

 

cleaning

 

agents

 

or

 

chemical

 

solutions.

 

We

 

recommend

 

using

 

OASE

 

PumpClean

 

for

 

remov

ing

 

calcium

 

deposits.

 

Cleaning

 

and

 

replacement

 

cycles

 

for

 

filter

 

media

 

such

 

as

 

foam

 

filters

 

are

 

dependent

 

on

 

the

 

size

 

of

 

the

 

aquarium

 

and

 

the

 

number

 

of

 

fish.

 

Therefore,

 

it

 

is

 

necessary

 

to

 

clean

 

and

 

replace

 

the

 

filter

 

media

 

as

 

required

 

to

 

ensure

 

optimum

 

filter

 

performance.

If

 

there

 

are

 

several

 

foam

 

filters:

 

Clean

 

or

 

replace

 

the

 

foam

 

filters

 

at

 

different

 

times.

 

This

 

saves

 

enough

 

useful

 

bacteria

 

to

 

ensure

 

good

 

biological

 

filtration

 

of

 

the

 

water.

 

Recommendation

 

for

 

clear

 

water:

 

Replace

 

the

 

filter

fleece

 

at

 

least

 

each

 

time

 

the

 

filter

 

sponges

 

are

cleaned.

 

Cleaning

 

or

 

replacing

 

the

 

filter

 

media

 

 

F

 

Carefully

 

pull

 

the

 

filter

 

unit

 

from

 

the

 

pump

 

unit

(magnetic

 

holder)

 

and

 

remove

 

from

 

the

 

aquarium.

 

Separate

 

the

 

filter

 

modules

 

(press

 

the

 

button).

Empty

 

the

 

filter

 

modules

 

over

 

a

 

wash

 

basin

 

and

 

rinse

 

the

 

foam

 

filters

 

or

 

filter

 

fleece

 

under

 

warm

 

wa

ter

 

or

 

replace.

Cleaning

 

the

 

heater

 

unit

 

 

C

 

BioPlus

 

Thermo:

 

Remove

 

the

 

heater

 

and

 

clean

 

ac

cording

 

to

 

the

 

separately

 

enclosed

 

instructions.

 

 

Also

 

clean

 

the

 

chamber

 

for

 

the

 

heater.

Summary of Contents for BioPlus 50

Page 1: ...BioPlus 50 100 200 BioPlus Thermo 50 100 200 43092_Gebrauchsanleitung_BioPlusBioPlusThermo indd 1 08 01 16 14 11...

Page 2: ...8 17 16 19 18 17 16 19 18 17 16 BioPlus Thermo 200 BioPlus 200 BioPlus Thermo 50 100 200 BioPlus 50 100 200 HeatUp 50 HeatUp 100 HeatUp 200 HeatUp 100 BioPlus 50 100 200 BioPlus Thermo 50 100 200 Heat...

Page 3: ...3 B BPL0002...

Page 4: ...4 BioPlus 50 100 200 BioPlus Thermo 50 100 200 C 19 18 17 16 BioPlus BioPlus Thermo HeatUp 25 200 BPL0003...

Page 5: ...5 D BPL0004 E BPL0005...

Page 6: ...6 BioPlus 50 100 200 BioPlus Thermo 50 100 200 F 5 2 6 4 1 3 2 1 BPL0006...

Page 7: ...7 G 1 2 H 1 2 BioPlus 50 BioPlus Thermo 50 BioPlus 100 BioPlus Thermo 100 BioPlus 200 BioPlus Thermo 200 BPL0010 BPL0007...

Page 8: ...age and do not present a tripping hazard Only open the unit housing or its attendant components when this is explicitly required in the operating instructions DANGER Only carry out work on the unit th...

Page 9: ...lter or filter fleece soiled Clean Foam filter or filter fleece worn Replace Filter housing clogged Clean the filter housing Only BioPlus Thermo Insufficient water heating Heater defective not calibra...

Page 10: ...rts https www oase livingwater com MAINTENANCE AND CLEANING For cleaning and maintenance first separate the filter unit from the pump unit and then remove both units from the water Maintenance of the...

Page 11: ...Head height Max ft 2 3 3 6 Filter volume in3 18 29 40 Recommended for an aquarium volume of gal 15 30 55 Length of power connection cable ft 6 6 6 Dimensions Length in 4 7 4 7 4 7 Width in 4 3 4 3 4 3...

Page 12: ...er sur le cordon N essayezpasd ouvrirlebo tierdelapompe dumoteur Acheminez les c bles tuyaux de mani re ce qu ils ne soient pas endommag s et ne pr sentent aucun risque de chute N ouvrez le bo tier de...

Page 13: ...ures Nettoyer ou rempla cer les moyens de filtration D E B Les ventouses fournies servent fixer l appareil sur une surface propre et lisse Introduire les ventouses dans les trous de montage de l unit...

Page 14: ...logique de l eau Conseil pour l eau claire remplacer le tissu fibre fil trant au moins apr s chaque nettoyage des ponges filtrantes Nettoyer ou remplacer les moyens de filtration F Minutieusement tire...

Page 15: ...eur de refoulement maximal m 0 6 0 9 1 1 Volume du filtre l 0 3 0 48 0 66 Recommand pour des volumes d aquarium l 50 100 200 Longueur du raccordement au r seau m 1 8 1 8 1 8 Dimensions Longueur mm 120...

Page 16: ...Tienda los cables mangueras de modo que est n protegidos contra da os y no presenten un peligro de tropiezo Solo abra la carcasa de la unidad o sus componentes auxiliares cuando esto se requiera expl...

Page 17: ...suministradas sirven para fijar el equipo en una superficie limpia y lisa Introduzca las ventosas en los agujeros de montaje de la unidad de bomba con un movimiento de giro Tenga en cuenta la alineaci...

Page 18: ...lus Thermo 50 100 200 Recomendaci n para agua clara Sustituya el tejido filtrante como m nimo despu s de cada limpieza de las esponjas de filtrado Limpiar o sustituir los medios filtrantes F Quite cui...

Page 19: ...a de transporte m xima m 0 6 0 9 1 1 Volumen filtro l 0 3 0 48 0 66 Recomendado para volumen de acuario l 50 100 200 Longitud de la l nea de conexi n de red m 1 8 1 8 1 8 Dimensiones Longitud mm 120 1...

Page 20: ...55171 09 18 OASE North America INC www oase livingwater com...

Reviews: